6.5 4204 Relay Programming
Training Module
Connect the Relay module across the console bus.
Set 4204’s Dipswitch to device address 01 (switches 2 OFF and switches 3, 4, and 5 ON). Switch 1
determines the unit’s cover tamper response (ON= disabled, OFF=enabled).
Program Address “* 25” with a 3 for a 4204 (4 Output relay module)
Enter * 8 0 to move to “DEVICE PROGRAMMING”.
The console will display “ENTER DEVICE No.”
Enter the specific relay number 01, 02, 03, or 04 (The 4204 has 4 relays)
Press * and the console will display a summary START screen.
Press * and the console will display a summary STOP screen.
Press * to move to “DEVICE ACTION” then enter 0 = not used, 1 = close for 2 secs, 2 = stay closed, or 3
= pulse on/off.
Press * to move to “S TART EVENT” then enter 0 = not used, 1 = alarm, 2 = fault, 3 = trouble, or 4 =
restore.
A Zone List must be used in conjunction with an event. If a zone type/system operation is to be used
instead of an event, enter 0.
Press * to move to “START ZN LIST”. If a zone list is to be used to START the relay action, enter the
zone list number (1 to 3) (to be programmed in field *81) or 0 if a zone list is not being used.
Press * to move to “START ZN TYP” then, if a zone type/system operation is being used, enter the
appropriate 2-digit code as listed below.
Choices for Zone Types Choices for System Operation
00 = No Response (Not used) 20 = Arming Stay 42 = **System Battery Low
01 = Entry/Exit # 1 21 = Arming Away 43 = Communication Failure
02 = Entry/Exit # 2 22 = Disarming (Code+Off) 52 = Kissoff
03 = Perimeter 31 = End of Exit Time 58 = Duress
04 = Interior Follower 32 = Start of Entry Time ** Use 0 (any) for Partition No. (P) entry
05 = Trouble Day/Alarm Night 33 = Any Burglary Alarm *** Or at Disarming, whichever occurs earlier)
06 = 24Hr Silent 36 = **At Bell Timeout ***
07 = 24Hr Audible 38 = Chime
08 = 24Hr Aux 39 = Fire Alarm
09 = Fire Alarm or Trouble 40 = Bypassing
10 = Interior w/Delay 41 = **AC Power Fail
24 = Silent Burglary
Press * to move to “START PARTITON” then enter the partition number 1 or 2 (or 0 for any)
Press * to move to “STOP ZN LIST”. If a zone list will be used to STOP, or restore, the device action enter
the zone list number, 1, 2 or 3 (to be programmed in *81 mode). If not used enter 0.
Press * to move to “STOP ZN TYP” then, if a zone type/system operation is being used, enter the
appropriate 2-digit code as listed above.
Press * to move to “STOP PARTITION” then enter the specific partition number 1 or 2 (0 for any)
Press * to move to the “START” summary and if correct, press * to move to the “STOP” summary and if
correct, press *.
Console will display “ENTER DEVICE No.” so that the next device may be programmed. If there are no
more, Enter 0 0 to quit.
If a zone list is to be used, enter *81.
Console will display “ZONE LIST No.”, then enter specific zone list 01, 02,or 03.
Press * to display “ENTER ZN NUM.”, enter the two digit zone number and press * to move to the next zone
to be included in this zone list.
After all zone lists have been entered press 0 0 to quit.
Press * to move to the next prompt, “DELETE ZN LIST”, enter 0 to save the list or 1 to delete and return to
the “ZONE LIST No.” prompt.
If all zone lists have been entered, press 0 0 to quit.