ADEMCO VISTA-100 User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
Test Sensors 4-Digit Code + 5 (TEST) + 0
Keypad will beep every 40 seconds
Open sensors and keypad will sound
End test with 4-digit Code + 1 (OFF) key
(Wireless motions require no movement for 4 minutes prior to testing)
View Time/Date (Alpha Keypads only)
Master Code + # + 63
(Stays on for 30 seconds)
Set Time/Date (Alpha keypads will display menu, standard keypad will show nothing)
(WARNING: Do not set clock for 01/01/03 to 08/31/01 or panel cannot be downloaded!)
1. User Code + # + 63
2. Press * within 30 seconds
3. Enter 2-digit Hour (00 to 12)
4. Enter 2-digit Minute (00 to 59)
5. Press 1 for PM, press 2 for AM
6. Enter last 2 digits of Year (01 to ??)
7. Enter 2-digit Month
8. Enter 2-digit Day
9. Press * to exit or wait 10 seconds (Keypad will not give any confirmation beep)
Event Buffer (Alpha Keypads only)
1. Enter Master Code + # + 6 + 0
(Display shows last Alarm or event)
2. Press * for previous event or # for next
3. Press any key other than * or # to exit
Note: Display shows Contact ID event, click "Format" button for details
U = User
P = Partition (if available)
and time/date it occured
Make Macros (if Installer enabled, a Function key can be set to allow multiple functions with 1 button)
(Alpha Keypad) 1. While system is disarmed enter Master Code + # + 6 + 6
2. Select which Macro to program 1 or 2
3. This is current Macro programming (none), to program press *
4. Lets program system to bypass zones 02 and 03 and Arm Away
5. Press 6 (Bypass key) then 02 (Zone 02) and 03 (Zone 03)
6. Press D (bottom Function key) to save the command
7. Press 2 (Away key)
8. Press D (bottom Function key) to save the command
9. To exit press D (bottom Function key) for 2 seconds
Other possible commands that can be used
3 = Stay Arm
4 = Max Arm
7 = Instant Arm
Page view 1
1 2 3 4 5 6

Comments to this Manuals

No comments