Connecting the External Sounders
Connections for Self Actuating Bells and Bell/Siren combinations should be made as
outlined in Table 2.2 Connections for SABs and Table 2.3 Connections for Bell/Siren
Only.
Connecting Power to the System
Mains Power
Mains power for the system is 230 V a.c. 50 Hz (a 24-hour unswitched source). The
three-core mains cable should be brought into the control cabinet through the mains
entry point under the mains terminal block. The mains cable should be wired to the
three-way mains input terminal block. The secondary of the mains transformer should
be connected to the two terminals on the control panel PCB marked AC. No connec-
tion should be made to the GND terminal on the Accord PCB.
Note: Do not apply power to the transformer at this point.
Stand-by Battery
The system can be protected against mains failure by the addition of a Stand-by
battery; a maximum rating of 7.2 Ahr should be used.
Calculate the system quiescent current draw and multiply this by the number of hours
you require for stand-by cover, for example, 200 mA × 12 hours = 2.4 Ahr. Install the next
battery size up, in this case 2.8 Ahr.
Table 2.2 Connections for SABs. Table 2.3 Connections for Bell/Siren only.
snoitcennoC
BASrof
lenaPlleB
+LLEBffOdloH/ylppuSevitisoP
LLEB– evitageNlangiS/pirT
PMATLLEB– ffOdloH/ylppuSevitageN
LLEBRPMATnruteRrepmaTevitageN
BRTSlangiSevitageNebortS
rofnoitcennoC
ylnoneriS/lleB
lenaPlleB
+LLEBevitisoPebortS&lleB
-LLEBevitageNlleB
-PMATLLEBnommoCWSrepmaT
LLEBPMATR-C/NWSrepmaT
BRTSevitageNebortS
20
Zone Type Definitions
General Information
The Accord has eight zone types, these are:
0 = Not Used
1 = Final Exit (FX)
2 = Keyswitch
3 = Intruder (Alarm)
4 = Walk Through (IX)
5 = 24 Hour Tamper
7 = PA Audible
9 = Fire
1 Final Exit
The Final Exit zone type is used for the entry/exit route(s), they are usually assigned
to the front door or other main entry point(s). The zone becomes operational when the
system is set or setting.
For a Final Exit zone type to terminate a Full Setting procedure the Exit Time must be
set to infinite (410).
Activation of a Final Exit zone while the system is set initiates the unsetting proce-
dure; the keypads beep and all Walk Through zones are isolated. A valid User Code
must be entered at the keypad, or a Keyswitch zone activated, before the Entry Time
has elapsed.
If the system is Part Set or Night Set then the Exit Time is fixed at 30 seconds.
2  Keyswitch
The Keyswitch zone type is used to allow a keyswitch to Full Set the system. It has a
latching operation.
The keyswitch should be wired across the zone terminals; opening the Keyswitch
zone (open circuit) will start the Full setting procedure; closing the Keyswitch zone
(closed circuit) performs an instant unsetting of the system.
It is strongly recommended that the keyswitch should be fitted in a tamper protected
case with the tamper switch connected in series with the other tamper circuits at the
control panel.
3  Intruder
The Intruder zone type is used on devices which require an instant alarm if activated
when the system is Set. During the Set state zone activations cause internal sounders
and external sounders to activate.
4  Walk Through
The Walk Through zone type is used with the Final Exit zone type; when the system
is set and a Final Exit zone is activated the unsetting procedure is initiated and all