ADEMCO LYNXR-I
Security Systems
Programming Guide
AWAY
OFF
STAY
AUX
4
5
6
7
8
9
0
#
1
2
3
K14116 3/06 Rev. B
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - Security Systems

ADEMCO LYNXR-I Security Systems Programming Guide AWAYOFFSTAYAUX4567890#123 K14116 3/06 Rev. B

Page 2 - TABLE OF CONTENTS

- 10 - Field Function Programmed Values [ ] = Table 1 Default Value ✱99 EXITS PROGRAMMING MODE (ALLOWS RE-ENTRY) Installer Code + 8 + 0 + 0 or

Page 3 - DATA FIELDS

- 11 -✻✻✻✻56 ENHANCED ZONE PROGRAMMING PROCEDURE Use this mode to program zone information. Press ✻56 while in programming mode. Notes: (1) Ent

Page 4

- 12 -✻✻✻✻56 ENHANCED ZONE PROGRAMMING PROCEDURE F DELETE ZONE PARAMETERS 0 = Discard the delete request. 1 = Confirm the requested delete. If 0

Page 5

- 13 -✻✻✻✻80 DEVICE PROGRAMMING Use this mode to program Powerline Carrier Devices or zone lists for Chime by Zone feature. Press ✻80 while in prog

Page 6 - ENABLE/DISABLE LRR/IP

- 14 -✻✻✻✻81 ZONE LISTS Use this mode to define zone lists for Powerline Carrier Devices and/or for the chime by zone feature. Press ✻81 while in p

Page 7

- 15 -✻✻✻✻83 ENHANCED SEQUENTIAL MODE Use this mode to enter transmitter serial numbers. Press ✻83 while in programming mode. A 02 ZONE NUMBER E

Page 8 - DYNAMIC SIGNALING DELAY/

- 16 -✻✻✻✻84 ASSIGN ZONE VOICE DESCRIPTORS Use this mode to assign voice descriptors for each zone. These are the descriptors that are announced w

Page 9

-17-✻✻✻✻85 RECORD CUSTOM VOICE DESCRIPTORS Use this mode to record up to 5 custom voice descriptors for use with zone announcements. Press ✻85 whil

Page 10

- 18 -✻✻✻✻56 ENHANCED ZONE PROGRAMMING WORKSHEET Fill in the required data on this worksheet, then follow the programming procedure in the Installat

Page 11 - b zt

- 19 -Zone No. Zone Alarm Report Input Loop Transmitter Vocabulary (A 02) Type (zt) Code in hex (rc) Type (i) No. (l) Serial Number Inde

Page 12

- 2 -TABLE OF CONTENTS Data Fields ...

Page 13

- 20 -POWERLINE CARRIER DEVICES WORKSHEET FOR ✻✻✻✻80, and ✻✻✻✻81. Applicable only if Powerline Carrier Devices are to be used, or chime-by-zone feat

Page 14

- 21 -✻✻✻✻81 ZONE LISTS FOR OUTPUT DEVICES Fill in the required data on the worksheet below and follow the procedure in the installation manual as y

Page 15

-22-INCOMINGPHONELINETO HANDSETPHONELINEWEEKLY TESTING ISREQUIRED TO ENSUREPROPER OPERATIONOF THIS SYSTEMALL OUTPUT CIRCUITS ARE POWER LIMITED. PRE

Page 16 - b vv

-23-– Notes –

Page 17

‡K14116*Š K14116 3/06 Rev. B 165 Eileen Way, Syosset, New York 11791Copyright © 2006 Honeywell

Page 18

- 3 -TO LOAD A DEFAULT SET: While in Program mode, press ✻97, then enter a number 1-4 corresponding to the default table desired. See the Installati

Page 19

- 4 - Field Function Programmed Values [ ] = Table 1 Default Values ZONE SOUNDS AND TIMING (✱✱✱✱ 31– ✱ ✱ ✱ ✱ 39) ✱31 SINGLE ALARM SOUNDING/ZONE

Page 20

- 5 -Field Function Programmed Values [ ] = Table 1 Default Value ✱42 SECONDARY PHONE NUMBER

Page 21 - 5800 SERIES LOOP NUMBERS

- 6 -Field Function Programmed Values [ ] = Table 1 Default Value ✱49 SPLIT/DUAL REPORTING [0] 0 = Disable (None, unless primary fails)

Page 22 - FOR CANADIAN INSTALLATIONS

- 7 -Field Function Programmed Values [ ] = Table 1 Default Value TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES (✱59–✱76, & ✱89):

Page 23 - – Notes –

- 8 -Field Function Programmed Values[ ] = Table 1 Default Value ✱75 RF XMTR LO BAT RST RPT CODE | [1,0] ✱76 TEST RESTORE RPT CODE

Page 24 - ‡K14116*Š

- 9 -Field Function Programmed Values[ ] = Table 1 Default Value ✱90 EVENT LOGGING [3] 0 = None; 1 = Alarm/Alarm Restore; 2 = Trouble/Troub