N5944-8PRV1 Rev. B 6/99VISTA-120PARTITIONED SECURITY SYSTEMwith SCHEDULINGProgramming FormSystem Worksheets®
– 10 –VISTA 120 PROGRAMMING FORMSome fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section forprogramm
– 11 –VISTA 120 PROGRAMMING FORMSome fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section forprogramm
– 12 –VISTA 120 PROGRAMMING FORMSome fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section forprogramm
– 13 –VISTA 120 PROGRAMMING FORMSome fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section forprogramm
– 14 –PARTITION-SPECIFIC FIELDS(Duplicate these pages for each partition in the installation.)To programme these fields,1. Press *91 to select a parti
– 15 –PARTITION-SPECIFIC FIELDS(Duplicate these pages for each partition in the installation.)1*19 ARMS COMMON AREA 3 [0]Enter 1 if arming this
– 16 –PROGRAMMING WITH #93 MENU MODENOTE: The following fields should be preset before beginning: 2*00 Number of Partitions;1*32 receiver type. In add
– 17 –SYSTEM LAYOUT WORKSHEETSAs with any security system, you should first define the installation. This includes determininghow many partitions will
– 18 –SYSTEM DEFINITIONS BY PARTITION (enter values or yes/no)Option part 1 part. 2 part. 3 part. 4 part. 5 part. 6 part. 7 part. 8Entry Delay
– 19 –ACCESS CODES & USER DEFINITIONS FOR PARTITIONS 1-34-digit Access Partition 1 Partition 2 Partition 3Security Group 2-digit Global A
– 2 –TABLE OF CONTENTSRECOMMENDED PROGRAMMING PROCEDURE... 3SUMMARY OF P
– 20 –20ZONE DEFINITIONS FOR ZONES 1-24DIP DIP † Enter loop number on module Must be 1Parti- RF Trans. Type†RPM RPM for basic wired, serial n
– 21 –ZONE DEFINITIONS FOR ZONES 25-48DIP DIP † Enter loop number on module Must be 1Parti- RF Trans. Type†RPM RPM for basic wired, serial num
– 22 –ZONE DEFINITIONS FOR ZONES 49-72DIP DIP † Enter loop number on module Must be 1Parti- RF Trans. Type†RPM RPM for basic wired, serial numb
– 23 –ZONE DEFINITIONS FOR ZONES 73-96DIP DIP † Enter loop number on module Must be 1Parti- RF Trans. Type†RPM RPM for basic wired, serial numb
– 24 –ZONE DEFINITIONS FOR ZONES 97-120DIP DIP † Enter loop number on module Must be 1Parti- RF Trans. Type†RPM RPM for basic wired, serial num
– 25 –ZONE DEFINITIONS FOR ZONES 121-128DIP DIP † Enter loop number on module Must be 1Parti- RF Trans. Type†RPM RPM for basic wired, serial nu
– 26 –ZONE DEFINITIONS FOR DEVICE SUPERVISORY ZONES 810-831Parti-Zone Zone tion ReportNo. Type (1-8) Code Alpha Descriptor (3 words max.)8108118
– 27 –ZONE DEFINITIONS FOR KEYPAD PANIC/MISC. ZONES 988-999Parti-Zone Zone tion ReportNo. Type (1-8) Code Alpha Descriptor (3 words max.)9882n
àN5944-8PRV1{äN5944-8PRV1 Rev. B 6/99®ALARM DEVICE MANUFACTURING CO.A DIVISION OF PITTWAY CORPORATION165 Eileen Way, Syosset, New York 11791Copyrigh
– 3 –RECOMMENDED PROGRAMMING PROCEDUREThe following is a step-by-step procedure recommended for programming your VISTA-120 system.1 . Set the keypads
– 4 –12. Define user access codes.Refer to SECURITY ACCESS CODES section of the Installation Instructions toprogramme authority level, O/C reporting o
– 5 –PROGRAMME FIELD CATEGORIESIn the following pages, the programming fields have been arranged by category. Use this index to cross referencethe
– 6 –VISTA 120 PROGRAMMING FORMPartition-Specific fields are programmed separately for each partition (shown as shaded fields). See the PARTITION-SPEC
– 7 –VISTA 120 PROGRAMMING FORMSome fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section forprogrammi
– 8 –VISTA 120 PROGRAMMING FORMSome fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section forprogrammi
– 9 –VISTA 120 PROGRAMMING FORMSome fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section forprogrammi