– 3 –
Local programming requires the use of a 2-line alpha keypad (e.g., 6139) connected to the keypad terminals on the control.
To set all program fields to ADEMCO default values: Key
97
.
Field Function [ ] = Default Value Programmed Values Field Function [ ] = Default Value Programmed Values
SYSTEM SETUP (
20 –
30)
20
INSTALLER CODE [4 1 1 1]
| | |
Enter 4 digits, 0–9
21
QUICK ARM ENABLE [0]
1 = enable: 0 = disable
22
RF SYSTEM TYPE [0]
0 = none; 2 = 5800 (5881/5882)
4 = 5800 w/ RF Jam Detection
23
FORCED BYPASS FUNCTION [0]
0 = none; 1 = bypass open zones
24
RF HOUSE ID CODE [00]
|
00 = disable all wireless keypad usage;
01–31 = when using 5827 and 5827BD keypad
25
OUTPUT RELAY MODULE [0]
0 = none; 3 = 4204
26
VOICE MODULE ACCESS CODE [0]
|
1st digit: Enter 1-9; 2nd digit:
Enter only # + 11 for , # + 12 for #.
0 in either position = disabled
27
OUTPUT TO LONG RANGE RADIO [0]
0 = no; 1 = yes. If yes selected, dialer reports to
Primary No. (field 47) will also be sent via LRR. All
dialer and LRR reports will be in Contact ID format
(overriding field 46)
ZONE SOUNDS AND TIMING (
28 –
39)
28
SINGLE ALARM SOUNDING/ZONE [0]
0 = no; 1 = yes
UL Installations: Must be 0.
29
FIRE SOUNDER TIMEOUT [0]
0 = fire sounder timeout; 1 = no fire sounder timeout.
30
ALARM BELL TIMEOUT [1]
0 = none; 1 = 4 min; 2 = 8 min;
3 = 12 min; 4 = 16 min
38
ENTRY DELAY [2]
0 = 0 sec; 1 = 20 sec; [2 = 30 sec]; 3 = 45 sec;
4 = 60 sec; 5 = 90 sec; 6 = 240 sec
UL Installations: 45 seconds maximum.
EXIT Delay = ENTRY Delay + 15 sec.
39
AUDIBLE EXIT WARNING [1]
0 = no; 1 = yes
DIALER PROGRAMMING (
40 –
50)
In fields 40,
41,
and
42, enter up to the number of digits shown. Do not fill unused spaces. Enter 0–9; # +11 for ;
# +12 for #; # +13 for a pause.
40
PABX ACCESS CODE
| | |
Enter up to 4 digits if PABX code is needed to
access an outside line. If fewer than 4 digits are
entered, do not fill unused spaces.
Exit by pressing (and press 41, if entering next
field). To clear entries from field, press 40
.
41
PRIMARY PHONE NO.
| | | | | | | | | | |
Enter up to 12 digits for primary phone number.
If fewer than 12 digits are entered, do not fill unused
spaces. Exit by pressing
(and press 42, if entering
next field). To clear entries from this field, press
41
.
42
SECONDARY PHONE NO.
| | | | | | | | | | |
Enter up to 12 digits for secondary phone number.
If fewer than 12 digits are entered, do not fill unused
spaces. Exit by pressing
(and press 43, if entering
next field). To clear entries from this field, press
42
.
43
SUBSCRIBER ACCOUNT NUMBER
| | |
Enter 0–9; # +11 for B; # +12 for C; # +13 for D;
# +14 for E; [# +15 for F]. Enter
as 4th digit, if 3+1
dialer reporting is to be used. Enter 0 as the first digit
of a 4-digit account number for Nos. 0000-0999.
Exit by pressing
(and press next field).
To clear entries from field, press
43
.
Examples:
For Acct. No.
1234
, enter: 1 | 2 | 3 | 4
For Acct. No.
B234
, enter: #+11| 2 | 3 | 4
For Acct. No.
123
, enter: 1 | 2 | 3 |
45
PHONE SYSTEM SELECT [1]
If Cent. Sta. is
NOT
on a WATS line:
0 = Pulse Dial; 1 = Tone Dial;
If Cent. Sta.
IS
on
a WATS line:
2 = Pulse Dial; 3 = Tone Dial
Entry of a number other than the one specified will give unpredictable results.