– 3 –
Local programming requires the use of a 2-line alpha keypad (e.g., 6139) connected to the keypad terminals on the control.
To set all program fields to ADEMCO default values: Key
✱
97
.
Field Function [ ] = Default Value Programmed Values Field Function [ ] = Default Value Programmed Values
SYSTEM SETUP (
✱
20 –
✱
30)
✱
20
INSTALLER CODE [4 1 1 1]
| | |
Enter 4 digits, 0–9
✱
21
QUICK ARM ENABLE [0]
†
1 = enable: 0 = disable
✱
22
RF SYSTEM TYPE [0]
†
0 = none; 2 = 5800 (5881/5882)
4 = 5800 w/ RF Jam Detection
✱
23
FORCED BYPASS FUNCTION [0]
†
0 = none; 1 = bypass open zones
✱
24
RF HOUSE ID CODE [00]
|
00 = disable all wireless keypad usage;
01–31 = when using 5827 and 5827BD keypad
✱
25
OUTPUT RELAY MODULE [0]
†
0 = none; 3 = 4204
✱
26
VOICE MODULE ACCESS CODE [0]
|
1st digit: Enter 1-9; 2nd digit:
Enter only # + 11 for ✱, # + 12 for #.
0 in either position = disabled
✱
27
OUTPUT TO LONG RANGE RADIO [0]
†
0 = no; 1 = yes. If yes selected, dialer reports to
Primary No. (field ✱47) will also be sent via LRR. All
dialer and LRR reports will be in Contact ID format
(overriding field ✱46)
ZONE SOUNDS AND TIMING (
✱
28 –
✱
39)
✱
28
SINGLE ALARM SOUNDING/ZONE [0]
†
0 = no; 1 = yes
UL Installations: Must be 0.
✱
29
FIRE SOUNDER TIMEOUT [0]
†
0 = fire sounder timeout; 1 = no fire sounder timeout.
✱
30
ALARM BELL TIMEOUT [1]
†
0 = none; 1 = 4 min; 2 = 8 min;
3 = 12 min; 4 = 16 min
✱
38
ENTRY DELAY [2]
†
0 = 0 sec; 1 = 20 sec; [2 = 30 sec]; 3 = 45 sec;
4 = 60 sec; 5 = 90 sec; 6 = 240 sec
UL Installations: 45 seconds maximum.
EXIT Delay = ENTRY Delay + 15 sec.
✱
39
AUDIBLE EXIT WARNING [1]
†
0 = no; 1 = yes
DIALER PROGRAMMING (
✱
40 –
✱
50)
In fields ✱40,
✱41,
and
✱42, enter up to the number of digits shown. Do not fill unused spaces. Enter 0–9; # +11 for ✱;
# +12 for #; # +13 for a pause.
✱
40
PABX ACCESS CODE
| | |
Enter up to 4 digits if PABX code is needed to
access an outside line. If fewer than 4 digits are
entered, do not fill unused spaces.
Exit by pressing ✱ (and press 41, if entering next
field). To clear entries from field, press ✱40✱
.
✱
41
PRIMARY PHONE NO.
| | | | | | | | | | |
Enter up to 12 digits for primary phone number.
If fewer than 12 digits are entered, do not fill unused
spaces. Exit by pressing ✱
(and press 42, if entering
next field). To clear entries from this field, press
✱
41
✱
.
✱
42
SECONDARY PHONE NO.
| | | | | | | | | | |
Enter up to 12 digits for secondary phone number.
If fewer than 12 digits are entered, do not fill unused
spaces. Exit by pressing ✱
(and press 43, if entering
next field). To clear entries from this field, press
✱
42
✱
.
✱
43
SUBSCRIBER ACCOUNT NUMBER
| | |
Enter 0–9; # +11 for B; # +12 for C; # +13 for D;
# +14 for E; [# +15 for F]. Enter
✱
as 4th digit, if 3+1
dialer reporting is to be used. Enter 0 as the first digit
of a 4-digit account number for Nos. 0000-0999.
Exit by pressing
✱
(and press next field).
To clear entries from field, press
✱
43
✱
.
Examples:
For Acct. No.
1234
, enter: 1 | 2 | 3 | 4
For Acct. No.
B234
, enter: #+11| 2 | 3 | 4
For Acct. No.
123
, enter: 1 | 2 | 3 |
✱
✱
45
PHONE SYSTEM SELECT [1]
†
If Cent. Sta. is
NOT
on a WATS line:
0 = Pulse Dial; 1 = Tone Dial;
If Cent. Sta.
IS
on
a WATS line:
2 = Pulse Dial; 3 = Tone Dial
†
Entry of a number other than the one specified will give unpredictable results.