ADEMCO VISTA 10 User Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
– 5 –
RF EXPANSION ZONES:
Assign zone numbers (Zn) 10–25 to 5881L (up to 8); 5881M or 5881H (up to 16).
NOTE:
All numbers in brackets [ ] are default settings
.
ZONE ZONE ZONE ALARM RPT CODE INPUT LEARNED
DESCRIPTION NO. TYPE (Hex) TYPE RF INPUT
(Zn) (ZT) (RC) (In) (L)
RF Zones
1 0 [00] [01] [00] [03] [1]
1 1 [00] [01] [00] [03] [1]
1 2 [00] [01] [00] [03] [1]
1 3 [00] [01] [00] [03] [1]
1 4 [00] [01] [00] [03] [1]
1 5 [00] [01] [00] [03] [1]
1 6 [00] [01] [00] [03] [1]
1 7 [00] [01] [00] [03] [1]
1 8 [00] [01] [00] [03] [1]
1 9 [00] [01] [00] [03] [1]
2 0 [00] [01] [00] [03] [1]
2 1 [00] [01] [00] [03] [1]
2 2 [00] [01] [00] [03] [1]
2 3 [00] [01] [00] [03] [1]
2 4 [00] [01] [00] [03] [1]
2 5 [00] [01] [00] [03] [1]
EXPLANATION OF ZONE ASSIGNMENT TABLE HEADINGS
Zn = ZONE NO.
Wired Zone Nos. run from 01 to 06. Wireless zones run from 10 to 25.
Pre-assigned zones (if programmed): 7, 8, and 9.
With Field
22 set for RF (5800), use Zone Nos. 10-25.
ZT =ZONE TYPE
00 = Zone Not Used
01 = Entry/Exit
02 =
Do not use
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night
06 = 24-Hr Silent
07 = 24-Hr Audible
08 = 24-Hr Aux
09 = Fire
10 = Interior w/ Delay
20 = Arm–STAY*
21 = Arm–AWAY*
22 = Disarm*
23 = No Alarm Response
* 20, 21, and 22 used for 5800 RF systems only
RC = ALARM REPORT CODE
Two hex digits. For each hex digit, enter: 00–09 for 0–9; 10 for A; 11 for B; 12 for C; 13 for D; 14 for E;
15 for F.
If 00 is entered in the first pair of boxes, there will be no report for that zone.
For Contact ID reporting, this is an enabling code only. Enter any hex digit (other than 00) in the first pair of
boxes. The second pair of boxes is ignored.
In = INPUT TYPE
HW = Hardwired zone (automatic for zones 1 – 6)
Enter 3 for RF: Supervised RF (default)
Enter 4 for UR: Unsupervised RF
Enter 5 for BR: Button-Type RF
L = RF INPUT LOOP
Used with 5800 RF Input Devices. Record transmitter input number.
Page view 4
1 2 3 4 5 6 7 8 9 10 11 12

Comments to this Manuals