ADEMCO Symphony 8142 Installation Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
11
Table of Device Addresses
Address Report
Device Programmed by…
00 100 RF Receiver *56 zone programming: input device type entry;
01 101 AUI Device 1 Automatic if AUI enable field *189 enabled for AUI 1
02 102 AUI Device 2 Automatic if AUI enable field *189 enabled for AUI 2
03 103 Alternative Communication Media (ACM) automatic if ECP Contact ID Output for ACM field *29 enabled
017-23 117-123 Telecommand Voice Module same as keypad enables; see below
Zone Expanders (4219/4229)/6164 Keypad: *56 zone programming: input device type entry, then:
08 108 module 2 zones 17 - 24 / 6164 zones 17-20 automatic if zone no. 17-24 entered as AW type or relay assigned
Relay Modules (4204)/6164 Keypad with Relay: *79 output device programming: device address prompt:
13 113 module 2 / 6164 using relay only (no zones) entered at device address prompt
Keypads: data field programming as listed below:
16 n/a keypad 1 always enabled for partition 1, all sounds enabled.
17 n/a keypad 2 data field *190
18 n/a keypad 3 data field *191
19 n/a keypad 4 data field *192
20 n/a keypad 5 data field *193
21 n/a keypad 6 data field *194
22 n/a keypad 7 data field *195
23 n/a keypad 8 data field *196
28 n/a 5800TM Module automatic
Addressable devices are identified by 1 plus the device address when reporting. Enter report code for zone 91 to enable addressable device
reporting (default = reports enabled). See field *199 for addressable device (ECP) 3-digit/2-digit identification keypad display options.
*57 FUNCTION KEY PROGRAMMING
Option Function A
P1 P2 P3
B
P1 P2 P3
C
P1 P2 P3
D
P1 P2 P3
Comments
01 Paging
02 Time Display
03 Arm AWAY
04 Arm STAY
05 Arm NIGHT-STAY
06 Step Arming
07 Device Activation Device:
08 Comm. Test
09 Macro Key 1 Assign each macro key to only a single partition.
10 Macro Key 2 Assign each macro key to only a single partition.
00 Emergency Keys: zone 95 zone 99 zone 96 paging
Personal Emergency n/a
Silent Alarm n/a
Audible Alarm n/a
Fire n/a
Emergency Keys: A = paired keys [1] / [] (zone 95); B = paired keys [] / [#] (zone 99); C = paired keys [3] / [#] (zone 96)
There are only four macros system-wide.
Start Function Key Programming mode by pressing
57 while in Data Programming mode.
Press Key to Pgm
0 = Quit 0
Press the desired function key, A-D.
NOTE: A key programmed as a function key is no longer available to
be used as an end-user macro key or panic key.
[] to continue
321
654
987
#0
*
READY
INSTANT
MAX
OFF
CODE
AWAY
TEST
CHECK
STAY
BYPASS
A
B
C
D
keypad_keys-00-001-V0
Partition
1
1 = function key active in partition 1
2 = function key active in partition 2
3 = function key active in common partition
[] to continue
Key "A" Func
Zone 95 00
Enter the desired function for this key:
00 = For the Function key selected, the function will be as follows (system default):
If A selected = Zone 95 (emergency key, same as [1] [] pair)
If B selected = Zone 99 (emergency key, same as [] [#] pair)
If C selected = Zone 96 (emergency key, same as [3] [#] pair)
If D selected = Single-button paging
01 = Single-button paging (sends a 999-9999 message to pager)
02 = Display time
03 = Arm AWAY (reports as User 00 if closing reports are enabled)
04 = Arm STAY (reports as User 00 if closing reports are enabled)
05 = Arm NIGHT-STAY (reports as User 00 if closing reports enabled)
06 = Step Arming (arms STAY, then NIGHT-STAY, then AWAY)
07 = Output Device Command (for device programmed as system operation type 66 in *80 Menu Mode)
08 = Communication Test (sends Contact ID code 601)
09 -10= Macro Keys 1-2 respectively (defined by [#] [6] [6] command)
[] to continue; returns to key number prompt with the next function key letter displayed.
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 23 24

Comments to this Manuals

No comments