TO DETERMINE TOTAL STANDBY LOAD
ON BATTERY, ADD 100mA TO TOTAL OF
AUX. POWER OUTPUT AND REMOTE
KEYPAD CURRENTS.
1234567891011121314151617181920 21
EARTH GROUND
SEE INSTRUCTIONS
FOR PROPER GROUNDING
TELEPHONE WIRING
(VIA RJ31X* JACK DIRECT
CONNECT CORD)
*IN CANADA, CA38A JACK
No. 4127: 20mA
No. 4137AD: 60mA
No. 6127: 20mA
No. 6128: 30mA
No. 6137: 85mA
OR
No. 5330: 105mA
BLACK: KEYPAD GROUND (–) RETURN
RED: KEYPAD PWR (+)
GREEN: DATA IN FROM KEYPAD
YELLOW: DATA OUT TO KEYPAD
REMOTE
KEYPAD
AUX. POWER
OUTPUT
10.5-13.8VDC
500mA MAX.
INTERRUPTS
FOR FIRE
ALARM RESET
NOTE:
KEYPAD
CURRENT MUST
BE INCLUDED IN
AUX. CURRENT
DRAIN
CALCULATIONS
}
GEL LEAD ACID TYPE.
BATTERY NORMALLY NEED NOT BE
REPLACED FOR AT LEAST 3 YRS.
BATTERY CAPACITY FOR EMERGENCY
STANDBY USE AT LEAST 4 HOURS.
BATTERY
12V, 4AH
OR 12V, 1.2AH
+
+
CONNECTOR TABS
USE UL LISTED
LIMITED ENERGY
CABLE FOR ALL
CONNECTIONS
FOR COMPLETE
INFORMATION, SEE
INSTRUCTIONS
N5478V4
PLUG-IN TRANS-
FORMER
16.5VAC, 25VA
(e.g. ADEMCO
No. 1321/TF2.
USE No. 1321CN
IN CANADA
TO 110VAC
UNSWITCHED
OUTLET (24HR)
+
CONNECTION OF THE FIRE ALARM SIGNAL TO A FIRE
ALARM HEADQUARTERS OR A CENTRAL STATION
SHALL BE PERMITTED ONLY WITH THE PERMISSION
OF THE LOCAL AUTHORITY HAVING JURISDICTION.
THE BURGLAR ALARM SIGNAL SHALL NOT BE CON-
NECTED TO A POLICE EMERGENCY NUMBER.
ALARM OUTPUT
10.5-13.8VDC, 2A MAX.
(600mA MAX FOR UL USAGE,
INCLUDING AUX. POWER)
STEADY FOR BURGLARY/PANIC,
PULSING FOR FIRE (e.g. USE ADEMCO
No. 702 OR 719 SIREN, OR 12V BELL)
FUSE
FOR REPLACEMENT,
USE SAME VALUE
3A
BLK
RED
GRN
YEL
1000
OHMS
EOLR
1000
OHMS
EOLR
ZONE 5
ZONE 6
HI
LO
HI
LO
TIP
(BROWN)
RING
(GRAY)
TIP
(GREEN)
RING
(RED)
}
}
INCOMING
PHONE LINE
LOCATED AT
LOWER RIGHT OF
CIRCUIT BOARD
HANDSET
BLACK
RED
+
1000
OHMS
EOLR
1000
OHMS
EOLR
ZONE 1
ZONE 2
HI
LO
HI
LO
1000
OHMS
EOLR
1000
OHMS
EOLR
ZONE 3
ZONE 4
HI
LO
HI
LO
• MAXIMUM LOOP RESISTANCE (EACH ZONE) 300 OHMS (PLUS EOLR)
• RESPONSE, ZONES 1-6: 300-500MSEC
• ZONE 3 CAN BE PROGRAMMED FOR N.C. SENSOR FAST RESPONSE TO AN
OPEN: 10MSEC MAX
• ZONE 5 CAN BE PROGRAMMED FOR USE AS A FIRE ZONE. SEE DIAGRAM
No. 4116
ARMING/DISARMING
KEYSWITCH
(SINGLE LED, LOCKSWITCH,
TAMPER)
BATTERY
(e.g. No. 90-12)
CHARGING
VOLTAGE
13.8VDC
NOTE: MULTIPLE KEYPADS MAY BE
USED, BUT EACH 5330 KEYPAD
MUST BE ON AN INDIVIDUAL HOME
RUN. USE MAX. OF 220FT. OF #22
WIRE OR 550 FT. OF #18 WIRE.
WARNING:
TO PREVENT RISK OF SHOCK,
DISCONNECT TELEPHONE LINE
AT TELCO JACK BEFORE
SERVICING THIS UNIT.
THIS EQUIPMENT SHOULD BE INSTALLED IN
ACCORDANCE WITH THE NATIONAL FIRE PRO-
TECTION ASSOCIATION’S STANDARD 74 (NATION-
AL FIRE PROTECTION ASSOC., BATTERYMARCH
PARK, QUINCY, MA 02269). PRINTED INFORMA-
TION DESCRIBING PROPER INSTALLATION,
OPERATION, TESTING, MAINTENANCE, EVACUA-
TION PLANNING AND REPAIR SERVICE IS TO BE
PROVIDED WITH THIS EQUIPMENT.
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES. OPERATION
IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) IT MAY NOT
CAUSE HARMFUL INTERFERENCE, (2) IT MUST ACCEPT ANY INTER-
FERENCE THAT MAY CAUSE UNDESIRED OPERATION.
COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION NO. AC398U-68192-AL-E
RINGER EQUIVALENCE: 0.7B.
WARNING:
OWNER’S INSTRUCTION NOTICE NOT TO BE
REMOVED. WEEKLY TESTING IS REQUIRED TO
ENSURE PROPER OPERATION OF THIS SYSTEM.
DOC LOAD NO.: 3
BLK
RED
GRN
YEL
No. 4281L or 4281M
RF RECEIVER
WIRELESS ZONES
4281L: UP TO 4
4281M: UP TO 8
{
OPTIONAL
SET RECEIVER’S DIP SWITCH
FOR DEVICE ADDRESS OF “0”
SEE RECEIVER’S INSTRUCTIONS
OR
AUX PWR
OUTPUT
TERMS
+
-
+
-
+
EOL
POWER
SUPER-
VISION
RELAY
MODULE
A77-716B
5
4
4-WIRE SMOKE
OR COMBUSTION
DETECTOR
1000
OHMS
EOLR
HEAT
DETECTOR
ZONE 5
*
+
RED
BLK
VIOLET
*
IF PROGRAMMED FOR FIRE
-