ADEMCO LYNX User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
- 2 -
7$%/(2)&217(176
DATA FIELDS.............................................................................................................................................................. 3
*56 ENHANCED ZONE PROGRAMMING...................................................................................................................8
*80 DEVICE PROGRAMMING.....................................................................................................................................9
*81 ZONE LISTS........................................................................................................................................................10
*83 ENHANCED SEQUENTIAL MODE .................................................................................................................... 10
*84 ASSIGN ZONE VOICE DESCRIPTORS ............................................................................................................. 11
VOCABULARY INDEX (for *84 Assign Zone Voice Descriptors) .............................................................................. 11
*85 RECORD CUSTOM VOICE DESCRIPTORS...................................................................................................... 11
*56 ENHANCED ZONE PROGRAMMING WORKSHEET.........................................................................................12
POWERLINE CARRIER DEVICE WORKSHEET FOR *80 and *81 .........................................................................14
5800 SERIES TRANSMITTER LOOP DESIGNATIONS DIAGRAM..........................................................................15
SPECIAL MESSAGES...............................................................................................................................................15
LYNX SUMMARY OF CONNECTIONS DIAGRAM....................................................................................................16
Refer to the Installation Instructions for detailed information on programming the
LYNX system, including full descriptions of all data fields.
8
/
LYNX-R is not intended for UL985 Household Fire applications.
TO ENTER PROGRAMMING MODE:
1. Power up, then depress
[
] and [#]
both at once, within 50 seconds of powering up.
OR
2. For factory defaulted system, enter:
Installer Code
(
4 + 1 + 1 + 2)
plus
8 + 0 + 0.
OR
If different
Installer Code
is programmed, enter:
New Installer Code + 8 + 0 + 0.
(if
98 was used to exit previously, method 1 above must be used to enter the program mode again)
3. Upon entry into Program mode, data field *20 will be displayed (the first data filed in the system) and both
keypad LEDs will flash.
TO PROGRAM THE DATA FIELDS:
1. Press [*] followed by the desired field number (e.g., *21), then make the required entry.
2. The keypad beeps three times after entering data, then displays the next data field in sequence.
3. For phone number and account number fields, press [*] to end the entry if less than number maximum
number of digits is entered.
4. To delete an entry, simply press [*] plus that field number and reenter the correct data. For phone
number and account number fields *40-*44, *88 and *94, press [*] + field number + [*].
INTERACTIVE MENU MODES:
There are six interactive menu modes as listed below. To enter these modes, first enter Program mode. While
in Program mode, press [*] plus the mode number desired (e.g., *56).
*56 Enhanced Zone Programming............. For programming zone characteristics, report codes, etc.
*80 Device Programming ........................... For programming Powerline Carrier Devices
*81 Zone List Programming .......................For programming zone lists for use with Powerline Carrier Devices
*83 Enhanced Sequential Mode................. For entering transmitter serial numbers
*84 Assign Zone Voice Descriptors............ For assigning voice descriptors to zones
*85 Record Custom Voice Descriptors....... For recording custom voice descriptors
TO LOAD A DEFAULT SET:
While in Program mode, press *97, then enter a number 1-4 corresponding to the default table desired. See the
Installation Instructions for the default tables. Enter 0 to exit *97 without loading a default table.
TO EXIT PROGRAMMING MODE:
98 Exits programming mode and
prevents
re-entry by: Installer Code + 8+ 0 + 0. If
98 is used to exit
programming mode, system must be powered down, then press [*] and [#] within 50 seconds of power
up to re-enter programming mode.
99 Exits programming mode and
allows
re-entry by: Installer Code + 8 + 0 + 0 or: Power-up, then press [*]
and [#] within 50 seconds of power up.
Page view 1
1 2 3 4 5 6 7 ... 15 16

Comments to this Manuals

No comments