ADEMCO LYNX User's Guide Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
Step Action
4.
(Cont.)
5) When the last zone has been entered, the display will remain on that zone. To exit this
mode and return to data field program mode, press 00 at the ZONE NUMBER prompt
6) Once all zones have been programmed, test each zone using the system’s Test mode.
Do not use the Transmitter ID Sniffer mode for this, since it will only check for
transmission of one zone on a particular transmitter, and not the zones assigned to each
additional loop.
1b
zz
c. Serial Number - This prompt can be used to enroll the transmitter serial number via RF
transmission or manually. If using RF Learning proceed to c. 1). If using the manual mode skip to
c. 2).
1) RF Learning - Two (2) transmissions (two key depressions at least five second apart) will be
required for BR type or four (4) transmissions (fault, restore and fault, restore) for UR or RF
type. BR type devices can be enrolled only by transmission from BR devices. Likewise, UR
and RF devices can only be enrolled by transmission from a UR or RF device.
If the learned serial number has a different loop number than that entered in *56 the system
will announce the Voice Descriptor, if it is programmed, followed by two beeps and will return
to Prompt (1A) and “L” will be displayed.
If the loop number captured by RF transmission and that entered in *56 mode match, the
system will announce the Voice Descriptor, if it is programmed, followed by three beeps and
return to Prompt (1A) and “LC” will be displayed. No additional transmissions are needed for
confirmation.
Note: BR type devices can be enrolled only by transmission from BR devices. Likewise, UR and RF devices can only
be enrolled by transmission from a UR or RF device.
1
b
2) Manual Entry - Enter the 7-digit serial number printed on the transmitter. If you enter an
incorrect digit, press the [#] key to backup to prompt (1A) and start over. When all seven
digits are entered press the [*] key.
3) Once all 7 digits have been entered, press the [*] key. If less than 7 digits are entered,
the keypad will emit a single long beep and return to the (1A) prompt without displaying
the “L”. If more than 7 digits have been entered, the first 6 digits will be saved along with
the last digit that was entered (entering 123456789 yields the serial number 1234569).
Note: If 52 seconds passes and no entry has been made, the system returns to prompt (1A).
F d. Delete Serial Number - This prompt can be used to delete the serial number programmed for the
zone.
1) Enter “0” to discard delete request or “1” to confirm
5. Exit Programming Mode as follows:
*
99 allows re-entry into the Program mode using Installer Code + 8 0 0.
*
98 inhibits re-entry into the Programming mode using the Installer Code.
6. Set RF House ID in the wireless keypads as follows:
a. 5804BD/BDV button key - Set the RF House ID per its instructions.
b. Powerline Carrier Devices - Set their House ID to “A,” (programmed as “0”) or use programming field *25 to
change the ID to avoid conflicts with existing installations.
7. Set the Real-Time Clock as follows:
a. Enter time/date setting mode by entering the User Code + FUNCTION + [63].
b. The hour prompt is displayed. Enter the correct hour, then press [*] to accept and advance.
c. For each subsequent prompt, enter the correct value, then press [*].
d. The system will exit this mode automatically after entering the year, or if no keys are pressed for 1 minute.
8. Test the system as follows:
a. After installation and programming, enter Installer Code + TEST.
b. To exit Test mode, enter Installer Code + OFF.
9. Assign desired User Codes by following the procedures on the next page and in the User Guide. Show the user
how to perform the various system functions.
Interactive mode programming
Interactive Mode Used to program
*
56 Enhanced Zone Programming
Zone characteristics, report codes and serial numbers
*
83 Enhanced Sequential Mode
5800 Series transmitter serial numbers
*84 Assign Zone Voice Descriptors Voice descriptors for each zone
Remote Programming (Downloading)
Perform site-initiated downloader session (to load central station ID) by Installer Code + [#] + [1].