ADEMCO LYNXR Setup Guide

Browse online or download Setup Guide for Security access control systems ADEMCO LYNXR. ADEMCO LYNXR Setup guide User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
K14117 3/06 Rev. A
ADEMCO LYNXR-I
Security Systems
Quick Start Guide
U
UU
U
L
LL
L
LYNXR-I is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N
LYNXRCHKIT-HC or LYNXRCHKIT-SHA) is installed.
Introduction
This Quick Start Guide can help you install the rechargeable LYNXR-I quickly and easily by providing the basic
steps for installation using the built-in defaults. For more detailed information and important notes, refer to the
LYNXR-I Installation and Setup Guide.
The following steps assume that one of the system’s default tables will be used.
For programming data values and Powerline Carrier Devices other than those listed in the default tables, see the
Installation Instructions.
Default Table Summary
Zone Table 1 Table 2 Table 3 Table 4
2 front door front door front door front door
3 back door back door back door back door
4 window garage door window window
5 motion detector motion detector window window
6 ------- smoke detector window window
7 ------- ------- window window
8 ------- ------- motion detector motion detector
9 ------- ------- smoke detector smoke detector
26 loop 3 arm away loop 3 arm away loop 3 arm away loop 3 arm away
27 loop 2 disarm loop 2 disarm loop 2 disarm loop 2 disarm
28 loop 4 arm stay loop 4 arm stay loop 4 close device loop 4 close device
29 loop 1 no alarm response loop 1 no alarm response loop 1 no alarm response loop 1 no alarm response
30 loop 3 arm away loop 3 arm away loop 3 arm away loop 3 arm away
31 loop 2 disarm loop 2 disarm loop 2 disarm loop 2 disarm
32 loop 4 arm stay loop 4 arm stay loop 4 close device loop 4 close device
33 loop 1 no alarm response loop 1 no alarm response loop 1 no alarm response loop 1 no alarm response
92 duress duress duress duress
99 silent alarm audible alarm silent alarm silent alarm
Master User Code 1-2-3-4 1-2-3-4 1-2-3-4 1-2-3-4
Installer Code 4-1-1-2 4-1-1-2 4-1-1-2 4-1-1-2
Duress Code ------ ------ ------ ------
Entering Expert Program Mode: installer code + 8 0 0
Interactive Mode Used to Program
*
56 Enhanced Zone Programming Zone characteristics, report codes, and serial numbers
*
83 Enhanced Sequential Mode 5800 Series transmitter serial numbers
*84 Assign Zone Voice Descriptors Voice descriptors for each zone
Exiting Program Mode:
*
98 inhibits re-entry into the Programming mode using the Installer Code.
*
99 allows re-entry into the Program mode using Installer Code + 8 0 0.
NOTES: Table 4 supports the automatic paging feature (open/close events reported to pager phone number),and a Powerline Carrier Device programmed
as device 8, which closes and stays closed upon burglary alarms and restores after bell timeout. For other applications or actions (e.g., using a
pulsing siren), see the *80 Device Programming Menu Mode section of the Installation Instructions.
Primary and secondary report format for all tables is Ademco’s Contact ID® reporting.
Tables 1, 3 and 4 record only alarms, alarm restores, troubles, and trouble restores in the event log. Table 2 records all events in the event log.
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Security Systems

K14117 3/06 Rev. A ADEMCO LYNXR-I Security Systems Quick Start Guide UUUULLLL LYNXR-I is not intended for UL985 Household Fire applicatio

Page 2 - Installing LYNXR-I

Installing LYNXR-I Installation and Electrical Connections Step Action 1. Install the control as follows: a. Separate the front assembly from the

Page 3 - System Programming

INCOMINGPHONELINETOHANDSETPHONELINEWARNING:TO PREVENTRISK OF SHOCKDISCONNECTTELEPHONE LINEAT TELECOMJACK BEFORESERVICINGTHIS UNIT.WEEKLY TESTING ISRE

Page 4

Step Action 3. Enhanced Sequential Mode - Press *83, then follow the prompts as follows: A 01 a. Zone Number - Enter 2-digit zone n

Page 5 - 01009-012-V4

Step Action 3. (Cont.) 3) Once all 7 digits have been entered, press the [*] key. If less than 7 digits are entered, the keypad will emit a single

Page 6

Keypad Functions (when default programming is used) Security Functions Checking system status: STATUS (high level messages); press STATUS again

Page 7

Remote Phone Control Operation To remotely disarm system: + [1] To remotely arm in AWAY mode:

Page 8 - ‡K141170Š

‡K141170Š K14117 3/06 Rev. A 165 Eileen Way, Syosset, New York 11791Copyright © 2006 Honeywell

Comments to this Manuals

No comments