K14117 3/06 Rev. A
ADEMCO LYNXR-I
Security Systems
Quick Start Guide
U
UU
U
L
LL
L
LYNXR-I is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N
LYNXRCHKIT-HC or LYNXRCHKIT-SHA) is installed.
Introduction
This Quick Start Guide can help you install the rechargeable LYNXR-I quickly and easily by providing the basic
steps for installation using the built-in defaults. For more detailed information and important notes, refer to the
LYNXR-I Installation and Setup Guide.
The following steps assume that one of the system’s default tables will be used.
For programming data values and Powerline Carrier Devices other than those listed in the default tables, see the
Installation Instructions.
Default Table Summary
Zone Table 1 Table 2 Table 3 Table 4
2 front door front door front door front door
3 back door back door back door back door
4 window garage door window window
5 motion detector motion detector window window
6 ------- smoke detector window window
7 ------- ------- window window
8 ------- ------- motion detector motion detector
9 ------- ------- smoke detector smoke detector
26 loop 3 arm away loop 3 arm away loop 3 arm away loop 3 arm away
27 loop 2 disarm loop 2 disarm loop 2 disarm loop 2 disarm
28 loop 4 arm stay loop 4 arm stay loop 4 close device loop 4 close device
29 loop 1 no alarm response loop 1 no alarm response loop 1 no alarm response loop 1 no alarm response
30 loop 3 arm away loop 3 arm away loop 3 arm away loop 3 arm away
31 loop 2 disarm loop 2 disarm loop 2 disarm loop 2 disarm
32 loop 4 arm stay loop 4 arm stay loop 4 close device loop 4 close device
33 loop 1 no alarm response loop 1 no alarm response loop 1 no alarm response loop 1 no alarm response
92 duress duress duress duress
99 silent alarm audible alarm silent alarm silent alarm
Master User Code 1-2-3-4 1-2-3-4 1-2-3-4 1-2-3-4
Installer Code 4-1-1-2 4-1-1-2 4-1-1-2 4-1-1-2
Duress Code ------ ------ ------ ------
Entering Expert Program Mode: installer code + 8 0 0
Interactive Mode Used to Program
*
56 Enhanced Zone Programming Zone characteristics, report codes, and serial numbers
*
83 Enhanced Sequential Mode 5800 Series transmitter serial numbers
*84 Assign Zone Voice Descriptors Voice descriptors for each zone
Exiting Program Mode:
*
98 inhibits re-entry into the Programming mode using the Installer Code.
*
99 allows re-entry into the Program mode using Installer Code + 8 0 0.
NOTES: • Table 4 supports the automatic paging feature (open/close events reported to pager phone number),and a Powerline Carrier Device programmed
as device 8, which closes and stays closed upon burglary alarms and restores after bell timeout. For other applications or actions (e.g., using a
pulsing siren), see the *80 Device Programming Menu Mode section of the Installation Instructions.
• Primary and secondary report format for all tables is Ademco’s Contact ID® reporting.
• Tables 1, 3 and 4 record only alarms, alarm restores, troubles, and trouble restores in the event log. Table 2 records all events in the event log.