ADEMCO VISTA SERIES
VISTA-20P / VISTA-20PSIA
VISTA-15P / VISTA-15PSIA
Security Systems
Programming Guide
K5305-1PRV5 10/04 Rev. A
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - ADEMCO VISTA SERIES

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems Programming Guide

Page 2

∗∗∗∗79 Menu Mode (press ∗∗∗∗79 while in Programming mode) The *79 Device Mapping Worksheet is on page 14. ENTER OUTPUT NO. 01-18 = VISTA-20P relays

Page 3

*82 Alpha Descriptor Programming (continued) ADDING CUSTOM WORDS (up to 10 words) For custom words, the keys have the following functions: [4] moves

Page 4 - V20PSIA/V15PSIA

Setting Schedules (Installer Code + [#] + [6] [4]) ENTER SCHED NO. VISTA-20P: 01-16 = end-user schedules; 17-32 = installer-only schedules VISTA-15P:

Page 5 - Example:

*56 ZONE PROGRAMMING WORKSHEET (VISTA-15P supports up to 32 zones: 1-6, 9-34, 49-56) [default shown in brackets] Zone Zn Type Part. Report Hardwi

Page 6

*57 FUNCTION KEY WORKSHEET Option Function A P1 P2 com B P1 P2 comC P1 P2 comD P1 P2 comComments 01 Paging 02 Time Display

Page 7 - ZONE-003-V0

✱80 OUTPUT DEFINITIONS Fill in the required data on the worksheet below and follow the programming procedure in the installation manual as you ente

Page 8 - ZT P RC IN: L

CLASS 2 PLUG-IN TRANSFORMER16.5VAC, 25VA(e.g. ADEMCO No. 1321).(USE No. 1321CN IN CANADA)TO 110VAC UNSWITCHEDOUTLET (24HR) THIS EQUIPMENT SHOULD BE I

Page 9 - (press

TO ENTER PROGRAMMING MODE (using an alpha keypad connected to the control): A. POWER UP, then press [✱] and [#] at the same time, within 50 seconds o

Page 10

PROGRAMMING FORM Entries apply to the ADEMCO VISTA-15P/VISTA-15PSIA and ADEMCO VISTA-20P/VISTA-20PSIA controls, except entries shown in dashed boxes

Page 11 - Italicized

∗∗∗∗49 Split/Dual Reporting [0] 0 = Standard/backup reporting only (all to primary) Primary Phone No. 2nd Phone No. 1 = Alarms, Rest

Page 12

∗∗∗∗88 Program Mode Lockout Options [0] 0 = standard *98 installer code lockout (reentry only by [∗] + [#] within 50 seconds after power up

Page 13

MISCELLANEOUS SYSTEM FIELDS (*174-*181) ∗∗∗∗174 Clean Me Reporting Options [0] (for ESL smoke detectors) 0 = disable; 1 = Clean Me sign

Page 14

Configurable Zone Types Worksheets Configurable zone types 90 and 91 can be programmed via downloader software or from a keypad using data fields*182

Page 15

*56 Zone Programming Menu Mode (press *56 while in Program mode) The Zone Programming Worksheet is on page 13. For each of the following prompts, mak

Page 16 - ÊK5305-1PRV5VŠ

Wireless Key Programming Templates (press the [D] key from *58 Menu mode Summary Screen) This procedure programs the wireless keys, but a key is not a