VISTA-10SE Installation and Setup Guide 2-2 Mounting Control with RF Receiver To mount the control panel and RF receiver boards together in the cabin

Page 3 - Table of Contents

Section 2 – Installing the Control & Peripherals 2-3 Mounting the Keypads 1. Make sure addressable-type keypads (6128, 6137, 6138, and 6139) are

Page 4 - (if programmed)

VISTA-10SE Installation and Setup Guide 2-4 +–+456 7SUPPLEMENTARYPOWER SUPPLY–CONTROL TERMINAL STRIPAUX.AUX. DATAINDATAOUTIMPORTANT:MAKE THESECONNEC

Page 5 - List of Figures

Section 2 - Installing the Control & Peripherals 2-5 AC Powerup To turn on AC power, perform the following steps: 1. Plug the 1321/1321CN into a

Page 6

VISTA-10SE Installation and Setup Guide 2-6 Earth Ground Connections Metal Cold Water Pipe: Use a non-corrosive metal strap (copper is recommend-ed

Page 7 - Introduction

Section 2 – Installing the Control & Peripherals 2-7 Installing the 5881/5882 Receiver RF System Installation Advisories Follow the guidelines be

Page 8

VISTA-10SE Installation and Setup Guide 2-8 Installing the 5800TM Module Installation of this module is necessary only if you are using one or more 5

Page 9 - SECTION 2

Section 2 – Installing the Control & Peripherals 2-9 Transmitter Input Types All of the transmitters described have one or more unique, factory

Page 10 - DETAIL B

VISTA-10SE Installation and Setup Guide 2-10 If no touch tones are produced following access to the security system from on-premises (this problem ma

Page 11 - KEYPAD CONNECTOR CABLE

Section 2 – Installing the Control & Peripherals 2-11 TERMINALSON CONTROLEARTH GROUNDINCOMING TELECOM LINEHANDSETTIPRINGRJ31XJACKPLUGDIRECTCONNEC

Page 12 - AUX. DATA

ii RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations for the Location of Fire and Burglary Detection Devices Help Provide Proper Co

Page 13

VISTA-10SE Installation and Setup Guide 2-12 CONTROL/DIALER HEADERNOTE:REFER TO AAV MODULE INSTRUCTIONS FOR CONNECTIONS TO AUDIO SPEAKERS AND MICROPH

Page 14 - TO HI SIDE OF

3-1 SECTION 3 Programming Overview ••••••••••••••••••••••••••••••••••••••••••••••••• About Programming You can program the system at any time, even a

Page 15

VISTA-10SE Installation and Setup Guide 3-2 Type 05 Trouble by Day/ Alarm by Night Zone type 05 is usually assigned to a zone that contains foil-prot

Page 16

Section 3 – Programming Overview 3-3 Mechanics of Programming To program the system from a keypad: • You must use a 2-line Alpha display keypad. •

Page 17 - 87654321

VISTA-10SE Installation and Setup Guide 3-4

Page 18 - VIP MODULE

4-1 SECTION 4 Data Field Programming ••••••••••••••••••••••••••••••••••••••••••••••••• About Data Field Programming The following pages list this con

Page 19 - ON CONTROL

VISTA-10SE Installation and Setup Guide 4-2 FIELD TITLE and DATA ENTRIES EXPLANATION Output To Long-Range Radio 0 = not used 1 = using Long Rang

Page 20 - 4285 or 4286

Section 4 - Data Field Programming 4-3 FIELD TITLE and DATA ENTRIES EXPLANATION ✱42 Secondary Phone No. Enter up to 12 digits. Do not fill unused

Page 21 - Programming Overview

VISTA-10SE Installation and Setup Guide 4-4 Example 2. Pager displays: 1234–001–005 This indicates that Subscriber No. 1234’s system is reportin

Page 22

Section 4 - Data Field Programming 4-5 With ADEMCO Contact ID® Reporting: Enter any digit (other than 0) in the first box, to enable zone to report

Page 23

iii Table of Contents ••••••••••••••••••••••••••••••••••••••••••••••••• Conventions Used In This Manual ...

Page 24

VISTA-10SE Installation and Setup Guide 4-6 If an exit or interior zone contains a fault as the exit delay ends, the local bell and keypad sound con

Page 25 - Data Field Programming

Section 4 - Data Field Programming 4-7 FIELD TITLE and DATA ENTRIES EXPLANATION ✱74 Low Bat Restore Report Code 0 = no report For both digits: 1

Page 26

VISTA-10SE Installation and Setup Guide 4-8 If Priority (✱93, 2nd entry) is… And message is… Then… Acknowledged before delay expires Message is remo

Page 27 - (Secondary)

Section 4 - Data Field Programming 4-9 FIELD TITLE and DATA ENTRIES EXPLANATION ✱96 Initialize Download ID and Subscriber Account Number For Down

Page 28

VISTA-10SE Installation and Setup Guide 4-10

Page 29

5–1 SECTION 5 Zone Programming (✱56 and ✱58 Menu Mode) ••••••••••••••••••••••••••••••••••••••••••••••••• About Zone Programming Programming Wireless

Page 30

VISTA-10SE Installation and Setup Guide 5–2 PROMPT VALID ENTRIES EXPLANATION Zone Number 10 Zone Type Perimeter 03 Zone Type Zone Type (ZT)

Page 31 - (2nd entry)

Section 5 - Zone Programming 5–3 PROMPT VALID ENTRIES EXPLANATION 10 INPUT S/N L A022-4064 ? Loop Number Entry [✱] to accept and

Page 32

VISTA-10SE Installation and Setup Guide 5–4 5800 Series Transmitter Input Loop Identification All the transmitters illustrated on this page have one

Page 33

Section 5 - Zone Programming 5–5 ✱58 Expert Programming Mode Procedures This method is designed for use by installers with previous experience in pr

Page 34

VISTA-10SE Installation and Setup Guide iv Section 8 Alpha Descriptor Programming (✱ 82 Menu Mode)...8-1 Ab

Page 35 - Zone Programming

VISTA-10SE Installation and Setup Guide 5–6 PROMPT VALID ENTRIES EXPLANATION XMIT TO CONFIRM PRESS ✱ TO SKIP Confirm [✱] to continue The prom

Page 36

Section 5 - Zone Programming 5–7 PROMPT VALID ENTRIES EXPLANATION 10 Zone Type Zone Disabled 00 Zone Type [✱] to continue 4. Enter 00. This set

Page 37 - Testing the Zones

VISTA-10SE Installation and Setup Guide 5–8 NOTE: Be sure to remove one of the serial number labels from the new transmitter and affix it over the ol

Page 38 - (Yellow)

Section 5 - Zone Programming 5–9 PROMPT VALID ENTRIES EXPLANATION Keyd A022-4063 – Rcvd A022-4064 3 Not Confirmed If the serial numb

Page 39

VISTA-10SE Installation and Setup Guide 5–10

Page 40

6–1 SECTION 6 Output Device Programming (✱80 Menu Mode) ••••••••••••••••••••••••••••••••••••••••••••••••• About Output Device Programming This syste

Page 41

VISTA-10SE Installation and Setup Guide 6–2 STOP (STP) The "STOP" programming determines when and under what conditions the relay will be d

Page 42

Section 6 - Output Device Programming 6–3 PROMPT VALID ENTRIES EXPLANATION Output Device Displays Enter Relay No. (00 = Quit) 01 Enter Relay No.

Page 43

VISTA-10SE Installation and Setup Guide 6–4 PROMPT VALID ENTRIES EXPLANATION 02 Stop: Zn List No List 0 STOP by Zone List [✱] to continue If a

Page 44

7–1 SECTION 7 Zone Lists (✱81 Menu Mode) ••••••••••••••••••••••••••••••••••••••••••••••••• About Zone Lists Zone lists let you group individual zones

Page 45 - Output Device Programming

v List of Figures ••••••••••••••••••••••••••••••••••••••••••••••••• Figure 2-1 Installing the Cabinet Lock ...

Page 46

VISTA-10SE Installation and Setup Guide 7–2 Notes: • Any list may include any or all of the system's zone numbers. • A zone list can be assign

Page 47

8-1 SECTION 8 Alpha Descriptor Programming (✱82 Menu Mode) ••••••••••••••••••••••••••••••••••••••••••••••••• About Alpha Descriptor Programming This

Page 48

VISTA-10SE Installation and Setup Guide 8-2 PROMPT PROCEDURE Default Descriptor ↓ ✱ZN 01 ZONE 01 If a descriptor was not entered previously for

Page 49 - Zone Lists

Section 8 – Alpha Descriptor Programming 8-3 PROMPT PROCEDURE Program Alpha? 0 = No, 1 = Yes 0 14. Enter ✱00. The “Program Alpha?” prompt at l

Page 50

VISTA-10SE Installation and Setup Guide 8-4 ALPHA VOCABULARY LIST (For Entering Zone Descriptors) NOTE: Some rarely used words appearing in previous

Page 51 - Alpha Descriptor Programming

9-1 SECTION 9 System Communication ••••••••••••••••••••••••••••••••••••••••••••••••• Panel Communication with Central Station This section provides a

Page 52

VISTA-10SE Installation and Setup Guide 9-2 The following table lists codes for reports sent in different formats: Type of Report Code for 3+1/4+1 S

Page 53

Section 9 – System Communication 9-3 ADEMCO Contact ID® Reporting takes the following format: CCCC Q EEE GG ZZZ where: CCCC = Customer (subscriber)

Page 54 - (Word Space)

VISTA-10SE Installation and Setup Guide 9-4

Page 55 - System Communication

10-1 SECTION 10 System Operation ••••••••••••••••••••••••••••••••••••••••••••••••• Security Codes The system supports up to seven security codes; Ins

Page 56

vi Conventions Used In This Manual ••••••••••••••••••••••••••••••••••••••••••••••••• Before you begin using this manual, it is important that you und

Page 57

VISTA-10SE Installation and Setup Guide 10-2 Panic Keys There are three individual panic keys and/or, on some keypads, panic key pairs. If programme

Page 58

11-1 SECTION 11 Testing the System ••••••••••••••••••••••••••••••••••••••••••••••••• Local Tests After the security system installation is complete,

Page 59 - System Operation

VISTA-10SE Installation and Setup Guide 11-2 Go/No Go Test Mode By keying Installer code + [#] + [4], a mode similar to the test mode is entered, but

Page 60 - MAX TEST BYPASS

Section 11 – Testing the System 11-3 Other Displays (fixed-word keypad displays are in parentheses) Busy-Standby (dI). If this remains displayed for

Page 61 - Testing the System

VISTA-10SE Installation and Setup Guide 11-4 Troubleshooting Guide (continued) SYSTEM (including Wireless) SYMPTOM POSSIBLE CAUSE REMEDY 1. Transmit

Page 62

Section 11 – Testing the System 11-5 Troubleshooting Guide (continued) SYSTEM (including Wireless) SYMPTOM POSSIBLE CAUSE REMEDY 5b. If no respons

Page 63

VISTA-10SE Installation and Setup Guide 11-6

Page 64 - Troubleshooting Guide

12-1 SECTION 12 Remote Programming and Control (Downloading) ••••••••••••••••••••••••••••••••••••••••••••••••• About Remote Programming The VISTA–10

Page 65

VISTA-10SE Installation and Setup Guide 12-2

Page 66

13-1 SECTION 13 Specifications and Accessories ••••••••••••••••••••••••••••••••••••••••••••••••• VISTA-10SE Security Control 1. Physical: 12-1/2"

Page 67 - Control (Downloading)

1–1 SECTION 1 Introduction ••••••••••••••••••••••••••••••••••••••••••••••••• The VISTA–10SE is a control that supports up to 22 hardwired and wireles

Page 68

VISTA-10SE Installation and Setup Guide 13-2 Specifications and Accessories (continued) Compatible Devices 6127 REMOTE KEYPAD 1. Physical: 5-3/4&qu

Page 69 - SECTION 13

Section 13 - Specifications and Accessories 13-3 Specifications and Accessories (continued) 4285 and 4286 VIP Modules 1. Physical: 6-1/2" W x

Page 70

VISTA-10SE Installation and Setup Guide 13-4 Specifications and Accessories (continued) Compatible Sounders (continued) ADEMCO 745X3 Voice Siren D

Page 71

A-1 APPENDIX A Regulatory Agency Statements ••••••••••••••••••••••••••••••••••••••••••••••••• FEDERAL COMMUNICATIONS COMMISSION (FCC) PART 15 STATEME

Page 72

VISTA-10SE Installation and Setup Guide A-2 UL NOTICES 1. This is a "Grade A" residential system. 2. The 4285/4286 VIP Module and 7720PLUS,

Page 73 - Regulatory Agency Statements

B-1 APPENDIX B Limitations and Warranties ••••••••••••••••••••••••••••••••••••••••••••••••• WARNING THE LIMITATIONS OF THIS ALARM SYSTEM While this

Page 74 - UL NOTICES

VISTA-10SE Installation and Setup Guide B-2 ADEMCO LIMITED WARRANTY Alarm Device Manufacturing Company, a Division of Pittway Corporation, and its di

Page 75 - Limitations and Warranties

Index-1 INDEX ••••••••••••••••••••••••••••••••••••••••••••••••• 24-hour Audible Alarm... 3-2 24-hour

Page 76 - ADEMCO LIMITED WARRANTY

Index Index-2 Limited Warranty ...B-2 Local Tests...

Page 77 - Index-1

TO DETERMINETOTAL STANDBYLOAD ON BATTERY,ADD 100mA TOTOTAL OF AUX.POWER OUTPUTAND REMOTEKEYPAD CURRENTS.USE UL LISTEDLIMITED ENERGYCABLE FORCONNECTI

Page 78

VISTA-10SE Installation and Setup Guide 1-2 Optional VIP Module • Supports the ADEMCO 4285/4286 VIP Module. • Provides access to the system via on-p

Page 79 - WARNING:

¬19^lN7227V6 7/01 165 Eileen Way, Syosset, New York 11791 Copyright © 2001 PITTWAY CORPORATION

Page 80 - ¬19^l

2-1 SECTION 2 Installing the Control & Peripherals ••••••••••••••••••••••••••••••••••••••••••••••••• Cabinet and Lock Installation UL For Resid