ADEMCO 4140XMPT2 User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
2nd Page Programming Fields (press 94)
IASSIGN RESPONSE IYPE FOR ZONES - -
(Enter 30-10: see Response Types below)
1*O1 1 “02
1*O3 1 “04
1 “05
I —— ——
I
40111481115611164111
1
—u
1*O6
1*O7 u
1*O8
1*O9
—— ——
88 ~ I I 2nd RCVR
89~1 2nd RCVR
90~] 1st RCVR
/701117811186111
72~’ ~1 80~~]
RESPONSE TYPES: 00 = Disabled zone 01 = Entry/EXii #l: 02. Entry/Exit
#2: 03 = PerfmeteC 04 = Interior Followec 05 = Day/NighL 06 = 24 haur &lent
Alarm; 07= 24 hour Audible Alarm; 08= 24 hour Autilia~ 09= Fire;
10. Interior, Delay 20==rm stafi 21=srm away 22=disarm: 23=rw alarm
response
NOTES: Use of 1 or 2 RF RCVRS requires enabling their respective faults (88-91 )
as troubles (type 5). Entar 00 if no annunciation is desired, S8 & 90 = RCVR not
receiving transmitter signals. 89 &91 = RCVR not responding, bad mnn. to panel.
MISCELLANEOUS WIRELESS OPTIONS
1*26
1*27
1*28
1*29
1’30
1*31
1*32
1*33
1’34
FIRST 4280 RF RECEIVER SELECT
•1
1=ye~ [O=no]
SECOND 4280 RF RECEIVER SELECT
•1
1.ye.q [O=no]
RF TX LOW BAITERY ANNUN.
1=immadlate; [O=when disarmed]; Must be ‘1” for UL
RF TX LOW BAITERY REPORT ENABLE
•1
1=enable; [O=disable]
Must be ‘1” for UL
RF RCVR CHECK-IN INTERVAL
Izl
02-15 times 2 hours; CMdisables supemision [06]
Max. “6’ (12 hr) for UL
RF TRANSMllTER CHECK-IN INTERVAL ~]
02-15 times 2 hours; 00 disables transmitter superwsion [12]
Max. ‘6” (12 hr) for UL
RF RECEIVER TYPE
•1
0=4280; 1=4281 ( must have correct revision level); 2=5881
TOUCH-TONE W/ROTARY BACKUP ENABLE
1=enable; [O=diaable]
COMM. SPLIT REPORT SELECTION
•1
[O=no~ 1=aIarms primary, others seconda~
2=opeticlose, test secondaV, others primary See “51 for comments.
AL4RM REPORT CODE&ID DIGITS FOR ZONES
65-80 & SUPV. & RESTORE CODES
[codes default 10zero]
1’35 CODE 1*36 ID 1*37 CODE 1’38 ID
1*39
—— ——
u-l
ml
ml
r-i-l
b-l
ml
El
l---m
I I I Bypass
—— ——
7011 /]11
78111111
—— ——
—— ——
72\l)ll180~llll]
DIALER CODES ( Armed Stay, Time Set& Event Logging)
1*4O 1*41
First Digit Second Digit
Armed STAY
mm
——
Time/Date set or event log reset
L!-ll_!_l
Event Izg 50% & W% full
!Zlm
——
I ‘44 WIRELESS KEYPAD
u
TAM PER DETECT ENABLE
I=enable [O=disablel
1 *46 AUXILIARY OUTPUT ENABLE
u
[O=ground start]; 1=openlclose trigge~ 2=console sounding
1 48 WIRELESS KEYPAD ASSIGNMENT
u
[O=disable~ enter partition in which RF keypad usad, 1-8.
1*4
9 DISABLE TROUBLE SOUNDER
•1
1*53
1’55
1*56
1’57
I*58
1*6O
1*66
1’67
I*7O
DOWNLOAD CALLBACK
u
1
=callback net required; [O=callback required] Must be “W for UL.
DATE FORMAT SELECTION
•1
[0= mmddyy~ 1 = ddmmyy
REAL TIME CLOCK SYNCH
[0= 60Hz Mains~ 1 = 50Hz Mains
ENABLE 5800 RF BUTTON GLOBAL ARM
•1
Enter” 1” to have the system armldisann following the butfon’;s
usei% giobal arm settings. Enter “IT if the button is not to be usad to’-
global arm the system.
ENABLE 5800 RF BU7TON FORCE BYPASS
If zone is faulted afler pressing button, console will beep once. User
should press button again within 4 sec. to force bypass those zones.
ALARM VERIFICATION
•1
Enter 1 if alarm verification is being used; [Enter O if not used.]
SILENCE BELLS DURINGALARM VERIFICATION
Enter 1 if bells are to be silenced during alarm verification; [Enter O if
not.]
VIDEO AL4RM VERIFICATION SELECTION
Enter 1 for video alarm verification; [Enfer Ootherwise.]
EVENT LOG TYPES
1=enable logging; O=dksable Alrrn Chck Byps O/C Systm
Page 3