ADEMCO VISTA 10 User Manual Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
– 8 –
OUTPUT RELAYS WORKSHEET FOR FIELDS
80 and
81.
Applicable only if 4204 relays are to be used.
80 OUTPUT RELAYS
– This is an Interactive Menu mode. Fill in the required data on the worksheet below and follow the
programming procedure in the installation manual as you enter the data in response to the displays and prompts that
appear in sequence.
Notes:
1.
For Relays, field
25 must be programmed for a 4204 relay module (enter 3).
2
. Tampers of contacts or an expansion unit cannot be used to operate relays.
START
either or both
STOP
either or both
OUTPUT
RELAY
RELAY
ACTION
(A)
ZONE
EVENT LIST
(EV) (ZL)
ZONE TYPE
SYSTEM OPERATION
(ZT)
RESTORE of
ZONE LIST
(ZL)
ZONE TYPE/
SYSTEM OPERATION
(ZT)
01
02
03
04
Where:
A = DEVICE ACTION
0 = No response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off.
EV = EVENT
0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble.
ZL = ZONE LIST
1, 2, or 3 (from Field
81) or 0 = Not used.
START
ZONE LIST: Upon alarm, fault, or trouble of ANY zone on this list, relay action
will
START
.
STOP
RESTORE of ZONE LIST: Upon restore of ALL zones on this list, device action
will
STOP
. It need not be same list as used for START.
ZT = ZONE TYPE/SYSTEM OPERATION
Choices for Zone Types are:
00 = Not Used 06 = 24-Hr Silent
01 = Entry/Exit #1 07 = 24-Hr Audible
03 = Perimeter 08 = 24-Hr Aux
04 = Interior Follower 09 = Fire
05 = Trouble Day/Alarm Night 10 = Interior w/ Delay
Note
:
Any
zone in "ZT" going into
alarm, fault, or trouble will
actuate relay.
Any
zone of that type that
restores will stop relay action.
Choices for System Operation are:
20 = Arming–STAY 36 = At Bell Timeout**
21 = Arming–AWAY 38 = Chime
22 = Disarming (Code + OFF) 39 = Any Fire Alarm
31 = End of Exit Time 40 = Bypassing
32 = Start of Entry Time 41 = AC Power Failure
33 = Any Burglary Alarm 42 = System Battery Low
34 = Code + # + 7 Key Entry 58 = Duress
35 = Code + # + 8 Key Entry
** Or at Disarming, whichever occurs first.
81 ZONE LISTS FOR OUTPUT RELAYS
Record desired zone numbers. More or fewer boxes than shown may be
needed, since any list may include
any
or
all
of system's zone numbers.
Zone List 01
: Started or stopped by zone numbers (enter 00 to end entries).
, , , , , , , , , ...etc.
Zone List 02
: Started or stopped by zone numbers (enter 00 to end entries).
, , , , , , , , , ...etc.
Zone List 03
: Started or stopped by zone numbers (enter 00 to end entries).
, , , , , , , , , ...etc.