SECTION 2: Mounting and Wiring
2–3
To wire, see the Summary of Connections diagrams at the back of this
guide, or the appropriate Systems Interconnection Diagram provided,
and follow the instructions below.
The TouchCenter draws up to 305mA (on models 6272CV, 6272CBV,
6272CSV . If you are planning to power it from your panels Aux Power
output, check your panels Installation and Setup Guide and verify that
this device and others do not exceed your panel's Aux Power output
capability. If it does, a supplementary power supply is needed.
Connect the wires to the TouchCenter terminal block as
follows:
1. Connect +12VDC to the TouchCenter using step a or b below.
a. If powering the keypad from the control panel, connect the
AUX + terminal of the control panel to the + terminal block
position (+12VDC terminal of the TouchCenter (red wire)).
b. If powering the keypad from a supplementary power supply,
connect the + terminal of the supplementary power supply to
the + terminal block position (+12VDC terminal of the
TouchCenter (red wire)).
6271CV-003-V0
YG
DATA IN (GREEN)
GROUND (BLACK)
+12VDC (RED)
DATA OUT (YELLOW)
Figure 2. Wiring the
TouchCenter