SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS
(FIXED-WORD DISPLAY KEYPADS)
SOUND CAUSE DISPLAY
LOUD, INTERRUPTED*
Keypad & External Sounder
FIRE ALARM FIRE and ALARM are displayed; protection zone in alarm is displayed.
LOUD, CONTINUOUS*
Keypad &External Sounder
BURGLARY/AUDIBLE
EMERGENCY ALARM
ALARM is displayed; protection zone in alarm is also displayed.
Also see "Exit Alarm Warning Displays and Sounds" on page 21.
ONE SHORT BEEP
(not repeated)
Keypad only
a. SYSTEM DISARM
b. SYSTEM ARMING ATTEMPT
WITH AN OPEN ZONE
c. BYPASS VERIFY
a. Only READY is displayed. Green READY indicator (if present) is lit.
b. NOT READY is displayed, open protection zone number is displayed.
Green READY indicator (if present) is not lit.
c. The bypassed protection zone numbers are displayed. (One beep for each number
displayed.) BYPASS displayed.
ONE SHORT BEEP
(once every 40 seconds)
Keypad only
SYSTEM IS IN TEST MODE Opened Zone identifications will appear.
ONE BEEP every 40 sec.
Keypad only
a. LOW BATTERY AT XMTR
b. SYST. MAIN BATT. WEAK
c. TROUBLE
a. BAT displayed with ID number of transmitter.
b. BAT displayed with no transmitter ID
c. CHECK displayed. Troubled protection zone is displayed.
TWO SHORT BEEPS
Keypad only
ARM AWAY OR MAXIMUM AWAY and (if MAXIMUM) INSTANT are displayed.
THREE SHORT BEEPS
Keypad only
a. ARM STAY OR INSTANT
b. ZONE OPENED WHILE SYS-
TEM IS IN CHIME MODE
c. ZONE OPENED WHILE SYS-
TEM IS IN TEST MODE
a. STAY and (if INSTANT) INSTANT are displayed. Red ARMED indicator is lit.
b. CHIME displayed. Pressing READY [] key will display opened zone.
c. Open protection zone number is displayed.
RAPID BEEPING
Keypad only
MEMORY OF ALARM FIRE and/or ALARM is displayed; zone in alarm is displayed.
SLOW BEEPING
Keypad only
a. ENTRY DELAY WARNING
b. EXIT DELAY ALERT
(if programmed)
a. No display during delay; Exceeding the delay time without disarming causes alarm.
b. AWAY or (if MAXIMUM) AWAY INSTANT is displayed. Slow beeps change to fast beeps
during last 5 seconds of exit delay.
*If bell is used as external sounder, fire alarm is pulsed ring (see page 29); burglary/audible emergency is steady ring.
Note:
Also see
Other Trouble Displays
and
Total Power Failure
under
TROUBLE CONDITIONS
on pages 27 and 28.