010 CONFIRMED SL:1
A022-4064
When the system sees activity on the appropriate input, it will beep
three times and display the confirmation message. Press
[]
or
the upper left-hand button of the program tool when you are ready
to enroll the next serial number device.
At any time during this step, you may press
[]
on the keypad or the upper left-hand button of the
program tool if you are satisfied with the serial and loop number combination that has been
enrolled, regardless of whether or not the enrolled input has been "confirmed." This will ready the
system to enroll the next serial number device.
If the incorrect device has been enrolled, press [#] on the keypad or the upper right-hand button of
the program tool to delete the serial number and return to the "LEARN S/N?" prompt. A single long
beep will be heard from the keypad to verify pressing of the upper right-hand button. Then, press
1
(Yes) or press the upper left-hand button of the program tool (a single short beep will verify the
system is ready for enrolling) and re-activate the proper device or device loop input.
The system will search for the next zone that does not have a serial number associated with it. If one is
found, the system will return to the “INPUT S/N” prompt for the remaining zones.
After all zones have been displayed, whether enrolled or not, the "ENTER ZN NO." prompt will appear.
Enter 000 to exit the Sequential Mode and return to Data Field Programming Mode.
When you have finished programming all zones, test each using the system's Test Mode. Do not
use the Transmitter ID Sniffer Mode for this, as it will only check for transmission of one zone on a
particular transmitter, NOT the zones assigned to each additional loop, and will NOT verify polling
loop type.
Report Code Programming
All report codes are entered using #93 Menu Mode Programming, either through Report Code Programming,
or through the Zone Programming while entering other zone information. In the VISTA-128FB, reports are
divided into six categories. These categories represent the main menu options found in the Report Code
Programming. Reports and the categories in which they are found are as follows:
ALARM CODES RESTR, SUPV. CODES
(for groups of 16 zones)
SYSTEM GROUP #1
Zone Alarm Reports Alarm Restore
Trouble
Trouble Restore
Bypass
Bypass Restore
Closing (arm away)
Opening (disarm)
System Low Battery
Low Battery Restore
AC Loss
AC Restore
Periodic Test
Power
Cancel
Program Tamper
SYSTEM GROUP #2 SYSTEM GROUP #3 SYSTEM GROUP #4
Arm STAY
Time Set, Log Reset
Log 50%, 90% Full
Event Log Overflow
Exit Error by Zone
Exit Error by User
Recent Close
Early Open
Early Close
Late Open
Late Close
Failed to Open
Failed to Close
Auto-Arm Failed
Schedule Change
Fire Walk Test Start
Fire Walk Test End
Off-Normal