11–
Standard Phone Line Connections
The wiring connections shown here are not applicable if the 4285 Phone Module
is used. Refer to the 4285 Phone Module section for information regarding phone
line connections, which are different than those shown here.
Incoming phone line and handset wiring is connected to the main terminal block
(via a RJ31X jack) as follows (also see Figure 4):
Term. 21: Local Handset (TIP – Brown*)
Term. 22: Local Handset (RING – Gray*)
Term. 23: Incoming Phone Line (TIP – Green*)
Term. 24: Incoming Phone Line (RING – Red*)
* Colors of wires in Direct Connect Cord.
TERMINALS
ON CONTROL
EARTH GROUND
INCOMING TELCO LINE
Handset
Incoming
Telco Line
TIP
RING
RJ31X
JACK
PLUG
DIRECT
CONNECT
CORD
TIP
RING
GROUND
▲▲
PREMISES
PHONES
{
{
BROWN (TIP)
GRAY (RING)
GREEN (TIP)
RED (RING)
26 27 28 29 30
21 22
23 24
25
IMPORTANT!
IF THE PANEL IS NOT CONNECTED TO A PROPER
EARTH GROUND, YOU MAY GET FALSE TELEPHONE
LINE CUT INDICATIONS (IF THE TELEPHONE LINE
MONITOR HAS BEEN PROGRAMMED IN FIELD 92).
Figure 4. Telephone Line Connections
Wiring The AC Transformer
ÊÊÊÊÊ1321 Wire the 1321 transformer to terminals 1 and 2 on the control board. See wiring
table below for wire gauge to use.
Caution must be taken when wiring the transformer to the control panel to guard
against blowing the fuse inside the transformer (the fuse is non-replaceable).
ÊÊÊÊ4300 If you are going to use a 4300 transformer interface (required if Powerline Carrier
devices are going to be used), connect the 4300 transformer’s terminals as
follows:
a. Terminals 1, 3 (AC), and 2 (Ground) to control board terminals 1, 2, and 25,
respectively (see Figure 5). See table below for wire gauge to use.
WIRING TABLE
Distance of Transformer Wire Gauge
From the Control Panel To Use
Up to 50 feet # 20
50–100 feet # 18
100-250 feet # 16
Wiring to the AC Transformer must not exceed 250 feet using 16 gauge wire. The
voltage reading between terminals 1 and 2 of the control must not fall below
16.5VAC or an "AC LOSS" message will be displayed.
Do not plug the transformer into the AC outlet until you are instructed to do so
later in the manual.