36–
Section 12. MECHANICS OF PROGRAMMING
This section provides information on how to use the system's programming
modes. It will enable you to understand how to enter and exit programming
mode, and how to program the data fields and how to use the user-friendly
interactive modes (
*
56,
*
80,
*
81,
*
82).
If wired expansion will be used, the following program field must be
programmed (as required) before doing any zone programming.
*
25 WIRED ZONE EXPANSION
In addition, the following fields must be programmed before completing the installation.
*
20 INSTALLER CODE
*
21 QUICK ARM ENABLE
*
23 FORCED BYPASS (must be disabled for UL installations, enter Ò0Ó).
General Programming Information
Characteristics for each installation are stored in non-removable, electrically
erasable, non-volatile EEROM memory. These must be programmed for the
particular installation to establish its specific alarm and reporting features.
It is possible to program the system at any time, even at the installer's premises
prior to the actual installation. Simply apply power temporarily to the control and
then program the unit as desired.
IMPORTANT: You cannot enter the programming mode unless both
partitions are disarmed.
There are two programming modes: data field programming and interactive
(menu) mode programming. Data field programming is used for setting various
system options and interactive programming is used for programming zone
information and programming relay outputs.
To program the system, you must use a 5137AD or 6139 2-line Alpha keypad
connected to the Partition 1 keypad terminals on the control (4, 5, 6, & 7). Also,
both partitions must be disarmed. The Alpha keypad need not necessarily
remain in the system after programming.
Programming can also be performed remotely from the installer’s office/home,
using an IBM personal computer, a modem, and V-Link downloading software.
See the
REMOTE PROGRAMMING AND CONTROL (DOWNLOADING)
section
.
Entering Program Mode
You may use one of the following methods:
a) Press both the [
*
] and [#] keys at the same time within 50 seconds after
power is applied to the Control, or
b) After power up, enter the Installer code (4 1 1 2) + 8 0 0.
This method is disabled if you exit the program mode using
*
98 instead of
*
99.
See “Exiting Program Mode” paragraph later in this section.
If a different Installer code is subsequently programmed, use it instead of 4112
to gain access to the Programming mode.
Following entry into program mode, data field
*
20 will be displayed (this is the first
data field in the system). The system will now accept entries for field
*
20.
Programming a Data Field
1. Press [
*
] plus Field No. (for example,
*
21), then make the required entry.
2. When you have completely programmed a data field, the keypad will “beep”
three times and then automatically display the next data field in sequence. To
go to a different field, press [
*
] plus the desired field No.