3. If the number of digits that you need to enter in a data field is less than the
maximum digits available (for example, the phone number field), enter the
desired data, then press [
*]
and the next data field number to be programmed.
4. If you try to enter a non-existent field, the keypad will display EE or Entry
Error. Simply re-enter [
*
] plus a valid field number.
Reviewing a Data Field/Erasing an Entry in a Data Field
Press [#] plus Field No. Data will be displayed for that field number. No
changes will be accepted in this mode.
To delete an entry in a field, press [
*
] plus Field No. + [
*
]. (Applies only to fields
*
40–
*
46, and
*
94).
Interactive Mode Programming (
*
56,
*
80,
*
81, and
*
82)
Typical prompt displayed
during interactive mode
programming
Enter Zn Num.
(00 = Quit) 01
Zone Number -
Press [
*
] plus interactive mode no. (for example,
*
56). The Alpha keypad will
display the first of a series of prompts requesting entries.
A detailed procedure (with displays of prompts) is provided in later sections of
this manual.
Interactive Mode Used To Program
*
56 Zone Programming Zone characteristics, report codes and alpha
descriptors
*
80 Relay Programming 4229 or 4204 Relay modules, or Powerline
Carrier devices
*
81 Zone List Programming Zone Lists for relay/powerline carrier activation
*
82 Alpha Programming Zone alpha descriptors
Loading Factory Defaults
To load the factory defaults, enter the programming mode, press
*
97, then exit
the programming mode.
Do not press
*
97 to load defaults if any programming has been done
previously—data already programmed into the system will be changed!
*
96 resets all the Subscriber Account numbers and CSID in preparation for an
initial download.
Programming System Setup Fields
The following program field must be programmed before doing any zone
programming.
*
25 WIRED ZONE EXPANSION 0
Use this field to select the type of expansion unit being used, as follows:
0 = none; 1 = 4219; 2 = 4229; 3 = 4204. Default is 0.
Exiting the Programming Mode
*
99 allows re-entry into the program mode using Installer Code + 8 0 0.
*
98 inhibits re-entry into the programming mode using the Installer code.