Section 18.
ALPHA DESCRIPTOR PROGRAMMING
This section provides instructions for programming alpha zone descriptors. This is recommended
for systems using Alpha keypads, and necessary if a 4285 Phone Module is used.
If using a 4285 Phone Module, select from those words in the Alpha Vocabulary list shown in
boldface type. The Phone Module will not provide annunciation of the other words.
If a 4285 Phone Module is added to an existing VISTA-20HWSE system, the Alpha
descriptors presently in the system should be re-programmed, selecting from those
words shown in boldface type in the Alpha Vocabulary list. The Phone Module will
not provide annunciation of any other words.
The ALPHA VOCABULARY LIST and CHARACTER CHART can be found on a following page.
Zone Descriptors
The Alpha Keypad used with the
VISTA-20HWSE
can have a user-friendly
English language description/location of all protection zones, keypad panics, and
supervision faults programmed into the system. Each description can be
composed of a combination of words (up to a maximum of 3) selected from a
vocabulary of 196 words stored in memory (see a following page). In addition, up
to 10 installer-defined words can be added to those already in memory. Thus,
when an alarm or trouble occurs in a zone, an appropriate description for that
zone's location will be displayed at the keypad.
Note:
Alpha Descriptor entry can be done locally at the Alpha Keypad or
remotely using Downloading software. The Alpha keypad procedure is
described below.
Programming Zone Descriptors (program menu mode
*
82)
The descriptor can be entered when the zone is being defined in field
*
56 but we
recommend that it be done using
*
82 menu mode.
To program zone descriptors, you simply enter the 3-digit reference number for
the desired word(s). The 3-digit number for each word is provided in the Alpha
Vocabulary list (on a following page).
1. With the system powered up, enter the programming mode by keying:
Installer code (4 1 1 2) + 8 + 0 + 0. The following display will appear:
Installer Code
20
Program Alpha ?
0 = No, 1 = Yes
00
2. Press
*
82.
The “Program Alpha ?” prompt will
appear.
Custom Words ?
0 = No, 1 = Yes
00
3. Press Ò1Ó (Yes).
The “Custom Words” prompt will
appear.
4. Press Ò0Ó (No).* The system will then
automatically display the descriptor for
zone 1.
* The procedure for adding custom words to
the built-in vocabulary will be found later
under “Adding Custom Words”.