83–
BLK
RED
GRN
YEL
AUX. POWER
OUTPUT
10.5-13.8VDC
600mA MAX.
INTERRUPTS
FOR FIRE
ALARM RESET
NOTE:
KEYPAD(S)
CURRENT (IN
BOTH
PARTITIONS)
AND ALL
OTHER
DEVICES
DRAWING
POWER FROM
TERMS 4 & 5
MUST BE
INCLUDED IN
AUX CURRENT
DRAIN
CALCULATIONS
OPTIONAL
FOR UP TO 8 ADDITIONAL ZONES
123456789101112131415161718192021 22 23 24 25
EARTH GROUND
SEE INSTRUCTIONS
FOR PROPER
GROUNDING
TELEPHONE WIRING
(VIA RJ31X JACK AND DIRECT
CONNECT CORD)
FOR CONNECTION OF
OPTIONAL 4285 MODULE TO
PHONE TERMINALS, SEE
INSTRUCTIONS.
REMOTE KEYPADS
EACH PARTITION CAN USE
4127, 4137AD, 5137AD, 6127,
6128, 6137, 6138, OR 6139
KEYPADS.
LOCAL PROGRAMMING
MUST BE DONE WITH A
5137AD OR 6139 CONNECT-
ED TO PARTITION 1, BUT
NEED NOT REMAIN IN THE
SYSTEM.
OPTIONAL 4285 MODULE
CONNECTS TO PARTITION 1
KEYPAD TERMINALS
(SEE INSTRUCTIONS).
BLACK: KEYPAD GROUND (–) RETURN
RED: KEYPAD PWR (+)
GREEN: DATA IN FROM KEYPAD
YELLOW: KEYPAD DATA OUT
REMOTE
KEYPAD
PARTITION 1
}
WARNING: TO PREVENT RISK OF
SHOCK, DISCONNECT TELEPHONE LINE
AT TELCO JACK BEFORE SERVICING
THIS UNIT.
CHARGING
VOLTAGE
13.8VDC
BATTERY
12V, 4AH
+
+
CONNECTOR
TABS
PLUG-IN TRANSFORMER
16.5VAC, 25VA (e.g. ADEMCO
No. 1321)
TO 110VAC
UNSWITCHED
OUTLET (24HR)
+
ALARM OUTPUT
10.5-13.8VDC, 2A MAX. (700mA MAX. FOR
UL USAGE, INCLUDING AUX POWER)
STEADY FOR BURGLARY/PANIC, TEMPORAL PULSE
SOUNDING FOR FIRE (e.g. USE ADEMCO No. 702
OR 719 SIREN, OR 12V BELL). SEE INSTRUCTIONS
TO TERM 4
TO TERM 5
TO TERM 6
TO TERM 7
ADEMCO No. 4219
WIRED EXPANSION MODULE
(8 ADD'L EOLR WIRED ZONES)
-OR-
ADEMCO No. 4229
WIRED EXPANSION/RELAY MODULE
(8 ADD'L EOLR WIRED ZONES PLUS 2
OUTPUT RELAYS)
-OR-
ADEMCO No. 4204 RELAY MODULE
(4 OUTPUT RELAYS)
RING
(GRAY)
TIP
(GREEN)
RING
(RED)
INCOMING
PHONE LINE
HANDSET
BLACK
RED
+
SET UNIT’S
DIP SWITCH
FOR DEVICE
ADDRESS OF “1”.
See instructions.
2000
OHMS
EOLR
2000
OHMS
EOLR
ZONE 1
ZONE 2
HI
LO
HI
LO
2000
OHMS
EOLR
2000
OHMS
EOLR
ZONE 3
ZONE 4
HI
LO
HI
LO
2000
OHMS
EOLR
2000
OHMS
EOLR
ZONE 5
ZONE 6
HI
LO
HI
LO
2000
OHMS
EOLR
2000
OHMS
EOLR
ZONE 7
ZONE 8
HI
LO
HI
LO
• MAXIMUM LOOP RESISTANCE: (EACH ZONE) 300 OHMS
(PLUS EOLR)
• RESPONSE, ZONES 1-8: 10, 350, OR 700 MSEC
(PROGRAMMABLE)
VISTA-20HW
SE
SUMMARY OF CONNECTIONS
CONNECTOR
FOR PARTITION
2 KEYPAD(S)
YEL
RED
BLK
GRN
GEL LEAD ACID TYPE.
BATTERY NORMALLY NEED NOT BE
REPLACED FOR AT LEAST 3 YRS.
BATTERY CAPACITY FOR EMERGENCY
STANDBY USE AT LEAST 4 HOURS.
TO DETERMINE TOTAL STANDBY
LOAD ON BATTERY, ADD 100mA TO
TOTAL OF AUX. POWER OUTPUT AND
REMOTE KEYPAD CURRENTS.
USE UL LISTED
LIMITED ENERGY
CABLE FOR ALL
CONNECTIONS
BATTERY FUSE
FOR REPLACEMENT,
USE SAME VALUE
(e.g. ADEMCO No. 90-12)
9-PIN CONNECTOR
USED FOR 4300
TRANSFORMER
CONNECTIONS (FOR
OPTIONAL POWER LINE
CARRIER DEVICES)
SEE INSTRUCTIONS.
123456789
USE 4142TR CABLE
REMOTE
KEYPAD
PARTITION 2
USE 4300 TRANSFORMER INTERFACE IN
PLACE OF 1321 WHEN POWER LINE CAR-
RIER DEVICES ARE BEING USED (SEE
INSTRUCTIONS FOR CONNECTIONS)
TIP
(BROWN)
}
}
CAN BE USED FOR GLASS BREAK DETECTORS
OPTIONAL:
No. 4285 MODULE (160mA)
AND/OR
No. 7720 PLUS/7820
LONG RANGE RADIO
MAY ALSO BE CONNECTED. SEE
INSTRUCTIONS ACCOMPANYING
THOSE DEVICES
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION.
COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION NO. AC398U-68192-AL-E
RINGER EQUIVALENCE: 0.7B.
FOR COMPLETE INFORMATION
SEE INSTRUCTIONS N7526-2V2
WEEKLY TESTING IS REQUIRED TO ENSURE
PROPER OPERATION OF THIS SYSTEM
.
3A
N7525-2V2 Rev. B 7/97
SMOKE
THIS EQUIPMENT SHOULD BE INSTALLED
IN ACCORDANCE WITH THE NATIONAL
FIRE PROTECTION ASSOCIATION’S STAN-
DARD 74 (NATIONAL FIRE PROTECTION
ASSOC., BATTERYMARCH PARK, QUINCY,
MA 02269). PRINTED INFORMATION
DESCRIBING PROPER INSTALLATION,
OPERATION, TESTING, MAINTENANCE,
EVACUATION PLANNING AND REPAIR
SERVICE IS TO BE PROVIDED WITH THIS
EQUIPMENT.
AUX PWR
OUTPUT
TERMS
+
-
TO HI SIDE OF SELECTED ZONE
TO LO SIDE OF SELECTED ZONE
+
-
-
+
EOL
POWER
SUPER-
VISION
RELAY
MODULE
A77-716B
5
4
4-WIRE SMOKE
OR COMBUSTION
DETECTOR
2000
OHMS
EOLR
HEAT
DETECTOR
ZONES 2–7
*
+
RED
BLK
VIOLET
*
IF PROGRAMMED FOR FIRE
CAN BE USED FOR 2-WIRE SMOKE DETECTORS
®
ALARM DEVICE MANUFACTURING CO.
A DIVISION OF PITTWAY CORPORATION
165 Eileen Way, Syosset, New York 11791
Copyright © 1997 PITTWAY CORPORATION
Figure 22. VISTA-20HWSE SUMMARY OF CONNECTIONS