Installation and Setup Guide
5-18
Zone List Programming
Zone List programming involves:
1. Selecting an appropriate zone list number;
2. Adding the desired zone numbers to be included in that list.
Start Zone List Program Mode by pressing
81
while in Data Programming mode. The following
prompts are displayed
:
*81 Menu Mode
PROMPT
VALID ENTRIES EXPLANATION
Zone List No.
(00 = Quit) 01
Zone List Number
01-12 = zone list number
[] to continue
Enter the Zone List Number to program (or 00 to
end these entries). Press [
] to advance.
In the following displays, zone list 01 has been
selected for programming.
01 Enter Zn Num.
(00 = Quit) 00
Zone Number
01-06, 9-24, 49-64 = zone
numbers followed by [] to
accept each zone
00 to continue
Enter each zone number to add to the zone list,
followed by pressing [
] (example, 01
, 02
, 03
).
After all zones are entered, press 00 to continue.
IMPORTANT: Do not include fire zones in zone
lists that are used to STOP device actions.
01 Del Zn List?
0 = No 1 = Yes 0
Deleting Zone Lists
0 = don’t delete list
1 = delete this zone list
[] to continue
To delete the zone list, enter 1. All zones in the
zone list will be deleted automatically and the
system returns to the Zone List No. prompt.
To save the zone list, enter 0.
01 Delete Zone?
0 = No 1 = Yes 0
Deleting a Zone
0 = don’t delete zones
1 = go to next prompt to delete
zones
[] to continue
To save the entire zone list, enter 0 and the
system returns to the Zone List No. prompt.
To delete a zone or zones in a zone list enter 1 to
continue.
01 Zn to Delete?
(00 = Quit) 00
Delete the Zone
01-06, 9-24, 49-64 zones to be
deleted from list followed
by [] to accept each zone
00 to continue
Enter each zone to be deleted from the list,
followed by [
]. After all zones to be deleted are
entered, enter 00 to return to the Zone List No.
prompt. so that another list can be programmed, if
desired.
Notes:
Any list may include any or all of the system's zone numbers.
A zone list can be assigned to more than one output relay.
When creating zone list 4 for linked zones, include only zones assigned to zone types 3, 4, or 5. Do not
include zones that have delays (entry/exit zones, interior w/delay) or 24-hour zones, as these zone types
may produce unpredictable operation and may not function as intended.
About Function Key Programming (
57 Menu Mode)
The system provides the ability to program each of the four keypad function keys to perform one of 12
system operations. The end user can then activate the function by simply pressing and holding the
programmed key for 2 seconds. Typical functions (listed below) include single-button arming, turning
lights on/off, or single-button paging.