ADEMCO VISTA 10 Setup Guide Page 35

  • Download
  • Add to my manuals
  • Print
  • Page
    / 80
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 34
51
SECTION 5
Zone Programming
(
56 and
58 Menu Mode)
•••••••••••••••••••••••••••••••••••••••••••••••••
About Zone Programming
Programming Wireless Zones
5800 Series transmitters have built-in serial numbers that must be enrolled into the system using the
56 or
58 programming modes in this section, or input to the control via the downloader.
Some transmitters, such as the 5816 and 5817, can support more than one zone (referred to as loops or
inputs). Refer to the 5800 Series Transmitter Input Loop Identification paragraph on a following page.
Each loop must be assigned a different zone number.
56 Zone Programming (Interactive Menu) is used to program zones, zone types, report codes, enroll 5800
RF Wireless Transmitter serial numbers, and identify the type of loop input device(s). This mode can also be
used to enter alpha descriptors for programmed zones; however, we recommend entering descriptors in
menu mode
82 (Alpha Descriptor Programming) after all zone programming is completed.
For a faster method of zone programming, you can use the
58 Expert Programming Mode instead of
56
Zone programming. The
58 Expert Programming Mode (Interactive Menu) is designed for those who have
had previous experience in programming control panels of this type.
NOTE: Alpha display prompts are shown in a double-line box.
56 Zone Programming Procedure
Zone Programming involves:
1.
Entering the programming mode by pressing
20
2.
Pressing
22 (RF System) to enable reception of 5800 series transmitters
3.
Pressing
56 to start zone programming
4.
Making appropriate entries at the prompts
5.
Confirming the serial number of wireless transmitter zones.
The following prompts are displayed:
PROMPT VALID ENTRIES EXPLANATION
SET TO CONFIRM?
0 = NO 1 = YES 0
Set to Confirm
0 = no
1 = yes
This display appears upon entry into
56 mode. The default is
0
(No). If you enter
1
(Yes), you are prompted to confirm each
transmitter after entering the serial and loop numbers (at the
XMIT TO CONFIRM
prompt later in this procedure).
We recommend that you confirm the programming of every
transmitter.
Enter Zn Num.
(00 = Quit) 10
Zone 10 entered
Zone Number
1-25, 7, 95, 96
00 = quit
[
]
to continue.
Zone Number (ZN):
Enter the zone number that you wish to
program.
Zones 7, 95, or 96 may be entered (these are all emergency (panic)
key zones.
Zone 10 has been entered as an example in display at left.
Zn ZT RC In: L
10 00 10 RF:
Summary Screen
[
] to continue.
A
summary display
appears, showing the status of that zones
programming when using wireless keys.
NOTE:
If you are programming hardwired zones 01
-
06, the display
appears as follows.
ZN ZT RC IN: L
02 00 10 HW:
Page view 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 79 80

Comments to this Manuals

No comments