Section 6 - Output Device Programming
63
PROMPT VALID ENTRIES EXPLANATION
Output Device Displays
Enter Relay No.
(00 = Quit) 01
Enter Relay No.
[
]
to continue
Upon pressing
80, this screen will appear. Enter the Relay
Number 01, 02, 03, or 04 for a 4204 (or 00 to end these entries).
The [
] key is used to accept an entry and advance to the next
prompt. The [#] key is used to revert back to the last question to
check or change an entry. Press [
] to go forward again.
02 A EV ZL ZT
STT 0 0 0 00
START Summary Screen
[
]
key to continue
This screen displays a summary of the current Relay START
programming
(for this example, relay 02 has been selected).
02 A EV ZL ZT
STP 0
00
STOP Summary Screen
[
]
to continue
This screen displays a summary of the current Relay STOP
programming.
02 Relay Action
No Response 0
Response To Fault
[
]
to continue
Enter the desired relay action as follows:
0 = No response 2 = Close and Stay Closed
1 = Close for 2 seconds 3 = Continuous Pulse on & off
(1 sec ON, 1 sec OFF)
02 Start Event
Not Used 0
START Event
[
]
to continue
Enter the event to START the relay:
0 = Not used; 2 = Fault; 1 = Alarm; 3 = Trouble
A zone list must be used in conjunction with an event. If a zone
type/system operation is to be used instead of an event, enter 0.
02 Start: Zn List
No List 0
START by Zone List
[
]
to continue
If a zone list will be used to START the relay action, enter the
zone list number (to be programmed in field 81): 1, 2, or 3. If
not used, enter 0.
02 Start: Zn Typ
No Used 00
START by Zone Type
[
]
to continue
If a zone type or system operation will be used to START the
relay action, enter the appropriate two-digit code (see table that
follows). If not, enter 00.
CHOICES FOR ZONE TYPES
00 = Not Used 05 = Trouble Day/Alarm Night 08 = 24-Hr Aux
01 = Entry/Exit 06 = 24-Hr Silent 09 = Fire
03 = Perimeter 07 = 24-Hr Audible 10 = Interior w/Delay
04 = Interior Follower
CHOICES FOR SYSTEM OPERATION
20 = ArmingSTAY 33 = Any Burglary Alarm 39 = Any Fire Alarm
21 = ArmingAWAY 34 = Code + # + 7 Key Entry 40 = Bypassing
22 = Disarming (Code + OFF) 35 = Code + # + 8 Key Entry 41 = AC Power Failure
31 = End of Exit Time 36 = At Bell Timeout** 42 = System Low Bat
32 = Start of Entry Time 38 = Chime 58 = Duress
**Or at Disarming, whichever occurs earlier.