Section 4 - Data Field Programming
4-3
FIELD TITLE and DATA ENTRIES EXPLANATION
42
Secondary Phone No.
Enter up to 12 digits. Do not fill unused
spaces.
09, # + 11 for
, # + 12 for #, # + 13 for a
pause (2 seconds)
If you enter fewer than 12 digits, exit by pressing [
] and
next field number (e.g., 43). To clear entries from field,
press
42
. See NOTE if field
41 also.
NOTE:
If you wish to send a report to a pager, see field
47
on a following page.
43
Subscriber Account No.
Enter digits 09; # + 11 for B; # + 12 for C;
# + 13 for D; # + 14 for E; or # + 15 for F.
Enter
as
the fourth digit if a 3-digit account no. (for 3+1
dialer reporting format) is used.
Enter 0 as the first digit of a 4-digit account number for
numbers 00000999.
This field is also used as the Long-Range Radio Subscriber
Account No.
Exit field by pressing
and next desired field number.
45
Phone System Select
If Central Station Receiver
is
not
on WATS
line: 0 = Pulse Dial; 1 = Tone Dial
If Central Station Receiver
is
on WATS line: 2
= Pulse Dial; 3 = Tone Dial
Selects the type of telephone service.
46
Report Format
0 = 3+1; 4+1 ADEMCO Lo Speed Standard
(this is the default)
1 = 3+1; 4+1 Radionics Standard
2 = 4+2 ADEMCO Lo Speed Standard
3 = 4+2 Radionics Standard
6 = 4+2 ADEMCO Express
7 = ADEMCO Contact ID
®
Reporting
8 = 3+1; 4+1 ADEMCO Lo Speed Expanded
9 = 3+1; 4+1 Radionics Expanded
Selects the format to be used to report to the central station.
Enter 1 digit (09).
(Enter
as the 4th digit of
43 if 3+1 dialer reporting is to
be used.)
See field
27, which may override this fields selection.
NOTE:
The maximum number of alarm and alarm restore
reports during one armed period is determined by field
92.
47
Split/Dual Reporting
0 = disable (Backup report only)
1 5 (refer to table at right for reporting to
the Primary and Secondary telephone
Numbers.
6 9 (refer to table at right for reporting to a
pager and Primary telephone no.).
You must enter the pager number as
the secondary phone number in field
42 for this function to operate
.
To Primary No. To Secondary No.
1 = Alarms, restore, cancel Other reports
2 = All except open/close, test Open/close, test
3 = Alarms, restore, cancel All reports
4 = All except open/close, test All reports
5 = All reports All reports
To Primary No. To Paging No.
(Secondary)
6 = All reports except Open/Close Alarms/open/close, troubles
7 = All reports Alarms, troubles
8 = All reports Alarms/open/close, troubles
9 = All reports except Open/Close Alarms, open/close for users
5 - 25
, troubles
A 10-digit code is sent to the pager that is coded in the following format:
4-digit Subscriber No. SSSS
EEENNN 3-digit
User or Zone No. (as entered in field
43)
3-Digit Event Code (EEE), as follows:
911 = Alarm (NNN = Zone No.)
001 = Open, System disarmed (NNN = User No.)
002 = Close, System armed (
NNN = User No.)
811 = Trouble (
NNN = Zone No.)
NOTE:
The first digit of the Subscriber No. entered in field
43 must be 19 (do not use 0); the last 3 digits
can be 09.
Failure to observe this requirement may interfere with paging services.
Example 1.
Pager displays: 1234911004
This indicates that Subscriber No. 1234s system is reporting an Alarm (911), due to zone 4 being faulted