3-1
SECTION 3
Programming Overview
•••••••••••••••••••••••••••••••••••••••••••••••••
About Programming
You can program the system at any time, even at the installer's premises prior to the actual installation. Programming
can also be performed remotely from the installers office/home, using an IBM personal computer, a modem, and
Compass downloading software.
The following is a list of the various Programming modes used to program this system:
Programming Mode
Used to
Data Field Programming
Program basic data fields used for setting the various system options. Some of
the data fields in this system have been programmed by default for specific
values. However, other fields must be programmed for each particular
installation to establish its specific alarm and reporting features.
56 Zone Programming
Assign zone characteristics, report codes, alpha descriptors, and serial numbers
for 5800 RF transmitters in step-by-step procedural form.
58 Expert Mode Programming
Assign zone attributes similar to
56 mode, while providing a faster
programming procedure and is intended for use by those more experienced in
programming controls of this type.
80 Output Relay Programming
Program the 4204 Relay Module that contains 4 relays
81 Zone List Programming
Program zone lists for relay control
82 Alpha Programming
Create alpha descriptors for easy zone identification.
Zone Response Type Definitions
You must assign a zone type to each zone, which defines the way in which the system responds to faults in that zone.
Zone types are defined below.
Zone Type Description/Characteristics
Type 00
Zone Not Used
Program a zone with this zone type if the zone is not used.
Type 01
Entry/Exit
Burglary
Zone type 01 is usually assigned to sensors or contacts on primary entry and exit doors.
Entry delay #1 is programmable from 0-99 seconds (field
*
35).
Exit delay is independently programmable from 0-99 seconds (field
*
34).
Exit and entry delays when armed in AWAY or STAY mode.
No entry delay when armed in INSTANT or MAXIMUM mode.
Exit delay regardless of the arming mode selected
.
Type 02
This zone type is not used.
Type 03
Perimeter
Burglary
Zone type 03 is usually assigned to all sensors or contacts on exterior doors and windows.
Instant alarm when armed in AWAY, STAY, INSTANT, or MAXIMUM mode.
Type 04
Interior
Follower
Zone type 04 is usually assigned to a zone covering an entry area (i.e.: foyer, lobby, or
hallway) that one must pass upon entry (after faulting the entry/exit zone) to reach the
keypad. It provides an instant alarm if the entry/exit zone is not violated first, and protects
an area in the event an intruder has hidden on the premises before the system is armed, or
gains access to the premises through an unprotected area.
Delayed alarm (using the programmed entry/exit time) if entry/exit (type 01) or interior-
with-delay (type 10) zone is faulted first.
Instant alarm in all other situations.
Active when armed in AWAY or MAXIMUM mode.
Bypassed automatically when armed in STAY or INSTANT mode.