VISTA-128BP/VISTA-250BP Installation and Setup Guide
3-24
Paging Service Advisory
If you are setting up the software for the first time,
contact your paging service provider for the following
two pieces of information:
The exact access number to be used with each
receiving device
The correct PIN number for each receiving device.
Pager Formats
The system supports pager formats numeric and
alphanumeric.
Numeric Format
SSSS P EEE ZZ, where:
SSSS The partition’s 4-digit subscriber number
(field 32)
P Partition number
EEE 3-digit event code
ZZZ 3-digit zone or user number
NOTE: If any of the digits for the subscriber number
are hex digits (A, B, C, D, E, F), they will be replaced
with 0, 1, 2, 3, 4, 5, respectively, on the pager display.
Numeric Format Event Codes
Event Code
Alarm 333
Trouble 555
Open 444
Close 777
Other 000
Alphanumeric
PP Date Time EA ZZZ SSSS AD
Where:
PP Partition number (e.g., P1)
Date Date the event occurred (e.g., 03/15/00)
Time Time the event occurred (e.g., 01:16AM)
EA Event alpha descriptor (see APPENDIX
D)
ZZZ Zone or user number
SSSS The partition’s 4-digit subscriber number
(in field 32)
AD The zone’s programmed alpha descriptor
If the event is an arming or disarming, a 6-
character descriptor can be sent for the user,
if programmed, instead of the user number.
The descriptor can be programmed only via
the Compass Downloader.
The installer code has a default of INSTLR
and user number 002 has a default of
MASTER for the 6-character descriptor.
Mounting the Alpha Pager Module
The Alpha Pager Module (APM) may be mounted in
the control cabinet if space is available or, if this is not
possible, on the side of the cabinet or adjacent to it.
Do not mount the Alpha Pager Module on the
cabinet door or attempt to attach it to the PC
board.
To mount the Alpha Pager Module, perform the
following steps:
Step Action
1 If you are mounting the Alpha Pager
Module inside the control cabinet, attach it
to the cabinet’s interior surface with 2-faced
adhesive tape.
2 If you are mounting the Alpha Pager
Module outside the cabinet, use the bracket
interface (Ademco Part Number K5350).
Wiring the Alpha Pager Module
The Alpha Pager Module connects via the 4142TR
cable to the J8 connector on the VISTA-128BP/VISTA-
250BP.
To wire the Alpha Pager Module, refer to Figure 3-30
and perform the following steps:
Step Action
1 Connect the 4142TR to J8 on the control.
2 Connect the Brown wire of 4142TR to the
Orange wire of the APM.
3 Connect the Green wire of the APM to TB1-
23 of the control panel.
4 Connect the Red and Black wires of the APM
to terminals 6 and 7 (auxiliary power (+) and
(-), respectively) of the control.
5 Connect the APM RJ11 connector labeled
LINE to the handset terminals on the control
panel (terminals 26 and 27).
6 Connect the handset side of telephone line to
APM RJ11 connector labeled PHONE
(Optional) (Brown and Gray wires of Phone
Cord).
7 If you are using a parallel or serial printer,
connect the printer according to the
instructions accompanying the APM.
The serial printer must be configured for a
baud rate of 1200, eight data bits, no parity,
and one stop bit. (8/N/1).
The serial printer and Home Automation
cannot be used on the same system. If you
want to use a printer and Home Automation,
you must use a parallel printer.