VISTA-128BP/VISTA-250BP Installation and Setup Guide
4-10
function the same as alpha keypads, except when the
code + # 73 is entered. This entry will allow
momentary access to ALL access points in the
partition to which the keypad is assigned. To program
the wireless keypad, enter the partition the keypad is
assigned to in field 1*48.
Using an RF Transmitter Zone
A button type RF transmitter (5804) can be used to
provide access or egress for up to 4 doors. One button
will control one door. Also, a button can be used to
provide access or egress due to a panic or duress
condition.
An RF transmitter (5816) can be used with a remote
switch to provide exit in case of a fire alarm using a
PassPoint event action. To program the RF
transmitter for access control, perform the following
steps:
Step Action
1 Enter Zone Programming in the #93 Menu
Mode.
2 Program the zone with a response type 27
(Access Point).
3 Enter the access point number (00-31) of the
door.
4 Indicate whether RF device is for entry or
exit.
5 Enter the partition number
6 Enter the input type: button RF (03).
7 Enter the loop number.
8 Enroll the serial number
See Zone Programming in the Programming Guide for
a detailed explanation.
RF buttons and pendants must be assigned
to a user number in order to function. See
SECTION 9: User Access Codes
for the
procedure.
An RF transmitter will not provide access or
grant if the system is in any test mode.
Control of Lighting and Appliances
Lighting and appliances can be controlled when an
access or exit event occurs. Lights or appliances can
be automatically turned on or off when a valid entry or
egress request is presented at an access point. To
control these devices, the VISTA-128BP/VISTA-250BP
relays or the ACS relays or triggers are used with
keypads and/or RF transmitters whose response type
is Access Point (27). To program the control of lighting
and appliances, perform the following steps:
Step Action
1 Enter Output Programming in the #93 Menu
Mode.
2 Program all the information for the relay.
3 Select the output type: ECP (1) (4204) or (2)
(X-10).
See Output Programming in the Programming Guide
for a detailed explanation.
Using the VISTA-128BP/VISTA-250BP for Stand-
Alone Access Control
The VISTA-128BP/VISTA-250BP can be used for
access control without interfacing to PassPoint ACS or
VistaKey. A user can trigger an access point (i.e., door
strike) for 2 seconds by entering User Code + [0]. To
program the VISTA-128BP/VISTA-250BP for Stand-
Alone access control, perform the following steps:
Step Action
1 Enter Output Programming in the #93 Menu
Mode.
2 Program the output type as 1, or 2.
3 For type 1, program the ECP address and
relay number.
4 For type 2, program the house and unit codes.
5
Program the relay number in field 176
(partition-specific).
See Output Programming in the Programming Guide
for a detailed explanation.
Programming for ECP Long Range Radio
Program the LRR in Device Programming in the
#93 Menu Mode Programming.
Field 56: Selects the time the panel should wait
before it attempts to send a message to the second
destination.
Field 57: Select the initial reporting destination
for messages.
Field 58: Select events for the primary sub’s ID
Field 59: Select events for the secondary sub’s
ID.
Programming for TeleSmart
The TeleSmart module has a fixed address of 24 (it
cannot be changed). Set Device Address 24 for Device
Type 11 in the control’s Device Programming mode.
Also, Device Address 23 must be set for Device Type
01, Alpha Console, but do not actually connect a
device to the control panel set to that address.