VISTA-128B Installation Instructions
17-4
In field *69 enter the phone number of the paging service for Bypass reports. Up to 17
digits may be entered.
In field *70 enter the Pager ID number of the paging service for Bypass reports. This is
the PIN number. Up to 10 digits may be entered.
In field *71 enter the phone number of the paging service for Open/Close reports. Up to
17 digits may be entered.
In field *72 enter the Pager ID number of the paging service for Open/Close reports. This
is the PIN number. Up to 10 digits may be entered.
In field *73 enter the phone number of the paging service for System reports. Up to 17
digits may be entered.
In field *74 enter the Pager ID number of the paging service for System reports. This is
the PIN number. Up to 10 digits may be entered.
In field *75 enter the phone number of the paging service for Test reports. Up to 17
digits may be entered.
In field *76 enter the Pager ID number of the paging service for Test reports. This is the
PIN number. Up to 10 digits may be entered.
In field 1*70 enable the events for the event log.
In field 1*72 enable the Printer On-Line option. This must be turned on to allow events
to be sent to the pager interface when they occur.
4100APG LED Indications
Below is a table outlining the LED indications:
LED Name
Steady Blinking Off Pulse
Power
OK On Battery (B/U) No Power
Line
Not in use (OK) In Use
Call
Call in Progress Page Retry Idle
Busy
Telephone Busy No Dial Tone OK
Page
Page Fail OK Page OK
Data
No Data Msg Data
Load
No Data Prog Data
TRBL
Trouble OK