Section 22 – Data Field Descriptions
22-9
*73 PAGER PHONE NUMBER FOR SYSTEM
| | | | | | | | | | | | | | | |
This field is used to enter the alpha numeric paging service phone number for System
reports. Enter up to 17 digits, 0-9; enter #11 for *, #12 for #, and #13 for a 2-sec.
pause. Do not fill unused spaces. Enter * after the last digit of the phone number.
*74 PAGER ID NUMBER FOR SYSTEM
This field is used to enter the Pager ID number for System reports. Enter up to 10
digits. If fewer than 10 digits are required, enter
*
after the last digit, (i.e., pager pin
number).
*75 PAGER PHONE NUMBER FOR TEST
| | | | | | | | | | | | | | | |
This field is used to enter the alpha numeric paging service phone number for Test
reports. Enter up to 17 digits, 0-9; enter #11 for *, #12 for #, and #13 for a 2-sec.
pause. Do not fill unused spaces. Enter * after the last digit of the phone number.
*76 PAGER ID NUMBER FOR TEST
This field is used to enter the Pager ID number for Test reports. Enter up to 10 digits.
If fewer than 10 digits are required, enter
*
after the last digit, (i.e., pager pin number).
*79 ZONE TYPE RESTORES FOR ZONE TYPES 1-8
1 2 3 4 5 6 7 8
Enter 1 to enable Restore reporting for individual zone types.
Enter 0 if no Restore report is desired for a zone type. Default = 0.
*80 ZONE TYPE RESTORES FOR TYPES 9/10
9
10
Enter 1 to enable Restore reporting for individual zone types.
Enter 0 if no Restore report is desired for a zone type. Default = 0.
*83 FIRST TEST REPORT TIME [00, 12, 00]
|||
Enter the day (00-07) and time (00-23 hours/00-59 min.) that the first Test report shall
be transmitted.
Enter
00 in all locations if the Test report is to be sent immediately upon exiting.
Enter
00
in the day location if the report is to be sent at the next occurrence of the time
that is set.
Note:
that day 01=Monday. See Report Code Programming (System Group 1) in the #93
Menu Mode Programming section for assigning the Test Report Code.
*84 SWINGER SUPPRESSION (partition-specific) [03]
|
This option limits the number of messages (alarms or troubles) sent for a specific
channel in an armed period (Swinger Suppression). Enter 01-15. If 00 is selected, all
alarm or trouble codes are reported.
Must be 00 (disabled) for UL installations.
*85 ENABLE DIALER REPORTS FOR PANICS & DURESS
[0]
(partition-specific)
95 96 99 Duress
Enter 1 for each panic/duress for which reporting is desired.
Note: Non-zero report code must be assigned to zone 992 (duress) to enable Duress
reporting.