VISTA-128B Installation Instructions
19-2
The factory-loaded defaults (*97) enable keypad addresses 00-03 only. A keypad set to one of
these addresses must be used to program the system.
Entering Data Field Programming Mode
Enter Program Mode using either method A or B:
A. Press both the [] and [#] keys at the same time within 30 seconds after power is
applied to the control.
B. Enter the [Installer Code] + [8] + [0] + [0] + [0] keys. The factory installer code
can be changed once in the Program Mode (field 00).
Local keypad programming can be disabled through V-LINK or Compass downloading software. If
this is done, programming can only be accomplished via the downloading software.
Moving from One Page of Programming to Another
The data fields are grouped into four levels (referred to as "pages"). The first page is accessed
as soon as Programming Mode is entered.
The second, and third pages of data fields are indicated at the keypad by a 1, and 2,
respectively, in front of the 2-digit field address. The words "ALT PROGRAM MODE" is
displayed along with a "100, or "200," depending on which page of program fields is accessed,
to indicate the higher page of fields.
1.
To access the next level of fields, press 94.
2.
Then press [
]
+ [XX], where XX = the last two digits of the program field, and make the
desired entry.
3.
To return to the previous page of fields, press 99.
press *94 to move to 2nd page; press *99 to move back to 1st page
second page of fields
(1*01-1*77)
press *94 to move to 3rd page; press *99 to move back to 2nd page
third page of fields
(2*00-2*24)
Viewing Data Fields
To view the contents of a data field, press [#] plus the 2-digit field address. The field's entries
will be displayed, but no changes can be made.
Entry Errors
If an address is improperly entered, the keypad will display “FC”.
If a program entry is improperly entered (for example, a larger number than that which
is permitted), the keypad display will go blank.
In either of the above cases, simply re-enter [
]
+ the correct field number.