UNIT CODE
Enter the numberical unit code of the Powerline Carrier device
(00-15).
Press
[
]
to continue.
The keypad will display the Start and Stop summary screens
again.
Press
[
]
to continue.
When all relays have been programmed, enter
00
at the "ENTER RELAY NO." prompt.
If defining a zone list, continue to the next section. If not, enter
00
+ [
] at the next two
prompts. You will then be asked "Quit Menu Mode?" Enter
1
for "Yes,"
0
for "No." Then
enter
*99
to exit programming completely.
If supervision of the 4204CF Relay Output is desired, enter a response type for that output's
corresponding supervisory zone. This is equal to 600 + [Relay ID No.]. For example, if you
are programming Relay ID No. 1, the relay's supervisory zone would be 601. Program this
zone for response type 05 (Day/Night) in
Zone Programming
.
Zone List Programming
After all relays have been programmed, upon entering
00
at the "ENTER RELAY NO."
prompt, you will be asked to enter a zone list. If a zone list number was used to start or stop
a relay, you must define the zones belonging to that list as follows:
Enter Zone LIST
00=QUIT 00
Enter the zone list number
01-08
. Enter
00
to quit.
001 Enter Zn Num.
000=QUIT 000
Using 3-digit entries, enter each zone to be included in this
zone list. Press [
] after each zone number is entered.
When all zones have been entered, enter
000
.
Press [
] to continue.
001 Del Zn LIST?
0=No 1=Yes
Enter
0
to save the zone list entered. Enter
1
to delete that
zone list.
001 Delete Zone?
0=No 1=Yes
Enter
1
to delete one or more zones in that zone list. Enter
0
if
no changes are necessary. If 1 is entered, the following screen
will appear, otherwise the "Enter Zone LIST" prompt will
reappear.
001 Zn to Delete?
000=QUIT 000
Enter each zone number to be deleted from the zone list,
pressing [
] after each number.
View Zn LIST
00=QUIT 00
This will appear if
00
is pressed at the “Enter Zone LIST
prompt. Enter the zone list number that you wish to view.
Press [
] to continue.
XXX Assigned Zone
000=QUIT 000
Press [
] to scroll through all zones in that list. Enter
000
+[
]
to quit.
Press
*99