20-1
SECTION 20
Zone Type Definitions
•••••••••••••••••••••••••••••••••••••••••••••••••
In This Section
Zone Number Designations
Zone Type Definitions
•••••••••••••••••••••••••••••••••••••••••••••••••
Zone Number Designations
The VISTA-128B supports up to 128 zones of hardwire, polling loop and/or wireless
protection, distributed among up to 8 partitions. The following table lists the zone numbers
and the types of sensors that can be used with each in this system, and some alternate
functions the zones may be used as:
Zone Sensors
1 2-wire Smoke Detectors (if used)
5 Audio Alarm Verification (if used)
7 Keyswitch (if used)
8 Latching-Type Glassbreak Detectors (if used)
1-9 Traditional Hardwired Zones
9 Programmable for Fast Response
1-128 5800 Series Wireless Devices
10-128 Polling Loop Devices
995 * + 1 Panic
996 # + 3 Panic
999 * + # Panic
Zone Type Definitions
Each zone must be assigned a zone type, which defines the way in which the system responds
to faults in that zone. In addition, there are three keypad-activated zones (panic keys; see
note) for each partition, a polling loop supervision zone, and four RF supervisory zones, two
for each RF receiver installed. Zone types are defined below.
Type 00: Zone Not Used
Program a zone with this zone type if the zone is
not used.
Type 01: Entry/Exit #1 Burglary
This zone type provides entry delay whenever the
zone is faulted if the control is armed in the
AWAY or STAY Modes. When the panel is armed
in the INSTANT or MAXIMUM Mode, no entry
delay is provided. Exit delay begins whenever the
control is armed, regardless of the arming mode
selected. These delays are programmable. This
zone type is usually assigned to sensors or
contacts on doors through which primary entry
and exit will take place.