VISTA-10SE Installation and Setup Guide
2-6
Earth Ground Connections
Metal Cold Water Pipe:
Use a non-corrosive metal strap (copper is recommend-
ed) firmly secured to the pipe to which the ground lead
is electrically connected and secured.
AC Power Outlet Ground:
Available from 3-prong, 120VAC, power outlets only. To
test the integrity of the ground terminal, use a three-
wire circuit tester with neon lamp indicators, such as
the UL-Listed Ideal Model 61035, or equivalent,
available at most electrical supply stores.
Installing the Hardwired Zones
Common Characteristics for Zones 16
Response time from 300 - 500 milliseconds (400
milliseconds nominal)
Zone 3 can be programmed (in field
52) for
normally-closed sensor fast response (10mSec max)
to an open (suitable for vibration type contacts).
Default response is 400mSec nominal, which should
be used for most standard contacts
EOLR supervised zones support both open-circuit
and closed-circuit devices.
As many 4-wire smoke detectors as can be powered
from Aux Power on the control (on zone 5).
Wiring Burglary and Panic Devices to Zones 16
To wire burglary and panic devices to zones 1-6,
perform the following steps, referring to the VISTA-
10SE Summary of Connections
diagram located
on the
inside back cover of this manual.
1. Connect sensors/contacts to the hardwired zone
terminals (8 through 16). See the Summary of
Connections diagram.
2. Connect closed circuit devices in series in the high
(+) side of the loop. The EOL resistor must be
connected in series with the devices, following the
last device. See the Summary of Connections
diagram.
Connect open circuit devices in parallel across the loop.
The 1000 ohm EOLR must be connected across the
loop wires
at the last device
.
If the EOLR is not at the end of the loop, the
zone will not be properly supervised, and the
system may not respond to an open circuit on the
zone.
Smoke Detectors
Wiring 4-Wire Smoke Detectors on Zone 5
The system will support as many 4-wire detectors as
can be powered from Auxiliary Power on the control on
zone 5. Refer to the detectors instructions for complete
details regarding its proper installation and operation.
1. Connect 12-volt power for the detectors from
Auxiliary Power terminals
4
and
5
(which will
interrupt power for fire alarm reset). Observe proper
polarity when connecting detectors. See Figure 2-8.
2. Connect detectors (including heat detectors, if used)
across terminals of zone 5. All detectors must be
wired in parallel.
Remove 1000 ohm EOL resistor if connected
across the zone terminals. You must connect
the EOL resistor across the loop wires at the
last detector.
3. To meet NFPA 72 requirements, you must use a
supervisory module to supervise power (e.g., System
Sensor No. A77-716B Relay module).
U
L
4-Wire Smoke/Combustion detectors are
not
permitted in UL installations.
+
+
1000
OHMS
EOLR
HEAT
DETECTOR
HEAT
DETECTOR
ZONE 5
RED
EOL
POWER
SUPERVISION
RELAY MODULE
A77-716B
VIOLET
4-WIRE SMOKE
OR COMBUSTION
DETECTORS
TO HI SIDE OF
TO LO SIDE
AUX PWR
OUTPUT
TERMINALS
5
4
+
+
BLK
+
4-wire_smoke_conn-V0
Figure 2-8. 4-wire Smoke Detector Connections (Zone 5)