SPECIFICATIONS:
Electrical
• Aux. power 12VDC, 600mA maximum
• Seven hour standby at 400mA aux. load with four amp hour
battery
• 16.5VAC/25VA transformer
• Alarm output 12VDC, 2.0 amps maximum
• For UL installations, combined aux. and alarm output cannot
exceed 700mA
Output Control
• Supports up to four relay boards (up to
16 relays)
• Optional X-10 transformer/interface
(part no. 4300) may be used to control
up to 16 X-10 receiving devices
Zones
• Eight hardwired zones (15 with zone doubling)
• Selectable response 10msec, 350msec, 750msec
• Assignable to any partition
• 20 selectable zone types plus four configurable zone types
• Programmable swinger suppression
Expansion Devices
• 4219 – Eight hardwired zones – 16mA
• 4204 – Up to four relays – 15mA standby (each active relay
draws an additional 40mA)
• 4229 – Eight hardwired zones and two
relays – 36mA (each active relay draws an additional 40mA)
Accessories
• 4286 VIP Voice Module – 220mA
• 5881ENL RF Receiver supports up to
eight zones – 60mA, 5881ENM supports
up to 16 zones – 50mA, 5881ENH up to
40 zones – 50mA
• 5883 Transceiver supports up to
40 zones – 80mA
• Supports Eagle 1225 and 1221 boards
Keypads
• 6160/6139 Custom English (required for programming) –
150mA/40mA (6160) 130mA/40mA (6139)
• 6150/6128 Fixed English LCD – 70mA/40mA (6150),
40mA/20mA (6128)
• 6150RF Fixed English LCD with built-in receiver
105mA/80mA
Agency Listings
• UL Residential Fire, Burglary and CSFM
Smoke Detectors
• Supports up to 16 two-wire smoke detectors
• Supports four-wire smoke detectors
Communications
• Touchtone or pulse
• Formats supported
– ADEMCO Contact ID
– ADEMCO 4 + 2 Express
– ADEMCO low speed
– Sescoa/Radionics
• 3 + 1, 4 + 1 and 4 + 2 reporting
• Reporting capabilities
– Split
– Dual
– Split/Dual – True dial tone detection
• Low battery reports 11.2 – 11.6VDC
• AC loss and restoral reporting supported
ORDERING:
Part No. Description
VISTA-20PS Control Panel
ADEMCO VISTA-20PS
Two Partition Control with Graphic Support
16