VISTA Gateway Module (VGM)
Access Control Interface
APPLICATIONS:
Once the appropriate configuration information has been
transferred from the PassPoint’s Main Logic Board (MLB) to the
VGM, the VGM passes the messages as indicated by the
configuration from the MLB to the Vista and from the Vista to the
MLB. It keeps a copy of its configuration in a small on board
serial EEPROM.
INSTALLATION:
The VGM obtains its power from the LOCAL power output
connection of its associated Access Control System Power
Supply (ACS PS) when mounted in a cabinet with a dedicated
ACS PS. When mounted in a cabinet along with an MLB or the
PassPoint Door Control Module (DCM), it obtains its power from
the ACS PS REMOTE power output. The VGM requires 10.5-14V
DC @ 100mA. The VGM can also connect to a Vista keypad
power source.
SPECIFICATIONS:
The VGM communicates with its MLB via a twisted pair network
connection. Physically, this connection adheres to Echelon Free-
Topology Transceiver specifications (Transformer-Coupled,
Differential-Pair, 78Kbps). Logically, the connection is made
through the use of the Echelon Lonworks Protocol. Each VGM
connected to the network is considered a “node” and is
identified by a unique 48-bit serial number which is present in the
VGM’s Neuron chip.
Part No. Description
PTVGM VISTA Gateway Module
ECP Power
ECP Ground
ECP Transmit
ECP Receive
Contact ID Dialer Interface
To Echelbonworks Free
Topology Twisted Pair Bus
To Vista Panel
}
Vista
Gateway Module
(VGM)
ORDERING:
Page view 52