ADEMCO VISTA-100 Service Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 80
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
19
New Enhancement Panel Linking
Panel Linking allows multiple control panels to be networked
together and controlled from any keypad in the system:
• Control multiple zones, partitions, buildings from a
central location
• Check status, arm and disarm any partition from any keypad in
the system (based on user’s authority level)
• Users can have a different authority level in each partition and
access to different partitions in each panel
• Global Arming - users can arm and disarm all the partitions in all
the panels they have access to, with one set of keystrokes
Applications
The VISTA-128BP control is well suited for a variety of applications
as a burglary control and is supported by a diverse line of ADEMCO
initiating devices. Applications include medical and professional
buildings, supermarkets, churches or synagogues, office buildings,
schools, universities, strip malls, larger residences and factory or
warehouse environments.
Installation
The VISTA-128BP alarm system has been designed to mount both
quickly and easily. It meets all applicable requirements for UL-
Commercial Burglary installations, use the VISTA-ULKT kit when
an attack resistant enclosure is required.
Agency Listings (all future)
Burglary:
• UL609 Grade A Local Mercantile Premises and Mercantile Safe
and Vault
• UL611/UL1610 Grades A, AA Central Station
• UL365 Grades A, AA Police Connect
• UL985 Household Fire
• UL1023 Household Burglar Alarm
• California State Fire Marshall (CSFM)
Electrical:
• Voltage Input: From ADEMCO No. 1361 Plug-In Transformer
(use 1361CN in Canada) or 4300 transformer (for X-10
installations) rated 16.5VAC, 40 VA
• Alarm Sounder Output: 10VDC-13.8VDC, 1.7 amps max.,
(UL1023, UL609 installations); 750mA less aux. current draw
(UL985 installations)
• Auxiliary Power Output: 9.6VDC-13.8VDC, 750mA max. For UL
installations, the accessories connected to the output must be
UL Listed, and rated to operate in the above voltage range
• Backup Battery: 12VDC, 4AH or 7AH gel cell. YUASA NP4-12
(12V, 4AH) or NP7-12 (12V, 7AH) recommended
• Standby Time: 4 hours min. with 750 mA aux. load using 7 AH
battery
• Circuit Protectors: PTC circuit breakers are used on battery
input to protect against reverse battery connections and on
alarm sounder output to protect against wiring faults (shorts). A
solid state circuit breaker is used on auxiliary power output to
protect against wiring faults (shorts)
Main Dialer
• Formats Supported: ADEMCO High Speed, ADEMCO
4 + 2 Express, ADEMCO Low Speed, ADEMCO Contact ID,
Sescoa and Radionics Low Speed
• Line Seize: Double Pole
• Ringer Equivalence: 0.7B
Cabinet dimensions:
• 12-1/2" W X 14 1/2" H X 3" D
4208SNF
Eight-Zone
Expander Module
6160
Console
Glassbreak Detectors
4944SN
Contact
5881ENHC
Commercial Wireless Receiver
(Max Two)
4204
Relay
Module
4204CF
Supervised
NAC Module
Supports Up To
16 Conventional
Two-Wire
Smoke Detectors
4209U
Group Zoning
Module
4190SN
Remote Point
Module
4193SN
Serial Interface
Module
4959SN
Overhead Door
Contact
Panel
Linking
Module
Panel
Linking
Module
VISTA-128BP
Symphony
ECP
Bus
5808LST
Wireless
Smoke
5890
Wireless PIR
5816
Door/Window
Transmitter
VISTA-128BP
5800
Series
Wireless
Devices
VISTAKey V-Plex
Access Control
Module
5817CB Universal
Contact Monitoring
Transmitter
5869
Commercial
UL Wireless
Hold-up Button
ADEMCO VISTA-128BP
128 Zone UL Commercial Burglary Control Panel
Page view 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 79 80

Comments to this Manuals

No comments