Additional Features
• Notification Appliance Circuits (two):
– Programmable
– Temporal code compliant
– Individually silenceable
• Programmable on-board auxiliary relay
• SIA false alarm reduction features:
– Exit error logic
– Exit delay reset
– Cross zoning
– Call waiting defeat
– Recent close report
• Supports commercial hardwired, addressable V-Plex
polling loop and wireless zones
• Hardwired zones
– Provides eight style B hardwired zones
– EOLR supervised for Fire and UL burglary installations
– Supports N.O or N.C. sensors
– Individually assignable to any eight partition
– Up to 32 two-wire smoke detectors each on zone one
and two (64 total)
– Up to 50 two-wire glass break detectors on zone eight
• Patented addressable V-Plex polling loop technology
– Supports 120 two-wire zones points
– Global polling technology for faster processing
– Increased current draw capacity (128mA)
– Supervised by panel
– Individually assignable to partitions, notification circuit
(bell) output or aux relay
– 4,000 ft capability without the use of shielded cable
– Extender/Isolation bus module
– Two-wire smoke detector zone/group expansion module
adds two or four zones
– Eight zone – Class A and B extender module
– Eight zone – Class B extender module
– One zone supervised contact monitor module
• UL Listed wireless expansion
– Supports up to 128 wireless zones/points using
5881ENHC receiver
– Supervised by control for check-in signals
– Tamper protection for transmitters
– Individually assignable up to eight partitions
– Supports UL864/NFPA approved wireless smoke
detectors
• Access Control integration
– Full integration with PassPoint Access Control
System Complete Gateway interface of Vista
and access functions
• Up to 8 doors using VistaKey V-Plex Access Control
• Event reporting
• Local printer of access or VISTA related event
• Scheduled uploading of events to central station
• Stored events for one call retrieval
• Communication
– Phone mapping by zone response type
– Supports VIP interactive phone voice module
– Panel operation during download
– Uploading equipment list to central station
– Communication to PassPoint via Vista Gateway Module
• CCTV integration
– Supports VistaView-100 ECP based CCTV switchers
ADEMCO VISTA-128FBP/V128FBP-24
128 Zone UL Commercial Fire/Burglary Control Panel
30
5192
Series
Smoke
Detectors
4208U
Eight-Zone
Expansion
Module
4193SN
Serial Interface
Module
5881
Wireless
Receiver
4204
Relay
Module
NAC (Bell) Circuit
4204CF
Notification Appliances
5192
Series
Smoke
Detectors
Alpha Paging
Module
Parallel Printer
VistaView-100
CCTV Switcher
7835CF Cellular
Radio
Phone Line to Central Station
Notification
Appliances
RS232
6220S Printer
4100SM
Printer
Interface
Module
Eight Class B Hardware Zones
416 Key
Switch
Option
5140 LED
Communicator
Status Module
7720ULF Long
Range Radio
Serial Printer
VistaKey V-Plex
Access Control
Module
Vista-128FBP
6160CR
Red Alpha Console
4208SNF
Eight-ZoneExpansion Module
With 2 Class A Zones
V-PLEX Loop