23
New Enhancement PANEL LINKING
Panel Linking allows multiple control panels to be networked
together and controlled from any keypad in
the system:
Control multiple zones, partitions, buildings from a
central location
Check status, arm and disarm any partition from any keypad in
the system (based on user’s authority level)
Users can have a different authority level in each partition and
access to different partitions in each panel
Global Arming - users can arm and disarm all the partitions in all
the panels they have access to, with one set of keystrokes
Applications
The VISTA-250BP control is well suited for a variety of applications
as a burglary control. A diverse line of ADEMCO initiating devices
support this extremely powerful control. Some of the applications
supported are medical and professional buildings, supermarkets,
churches or synagogues, office buildings, schools, universities,
strip malls, larger residences and factory or warehouse environments.
Installation
The VISTA-250BP alarm system has been designed to mount both
quickly and easily. It meets all applicable requirements for UL-
Commercial Burglary installations, use the VISTA-ULKT kit when
an attack resistant enclosure is required. (VISTA-250BP and
VISTA-128BP both meet this requirement).
Agency Listings (all future)
Burglary:
UL609 Grade A Local Mercantile Premises and Mercantile Safe
and Vault
UL611/UL1610 Grades A, AA Central Station
UL365 Grades A, AA Police Connec
UL985 Household Fire
UL1023 Household Burglar Alarm
California State Fire Marshall (CSFM)
Specifications
Electrical:
Voltage Input: From ADEMCO No. 1361 Plug-In Transformer
(use 1361CN in Canada) or 4300 transformer (for X-10
installations) rated 16.5VAC, 40 VA
Alarm Sounder Output: 10VDC-13.8VDC, 1.7 amps max.,
(UL1023, UL609 installations); 750mA less aux. current draw
(UL985 installations)
Auxiliary Power Output: 9.6VDC-13.8VDC, 750mA max. For UL
installations, the accessories connected to the output must be
UL Listed, and rated to operate in the above voltage range
Backup Battery: 12VDC, 4AH or 7AH gel cell. YUASA NP4-12
(12V, 4AH) or NP7-12 (12V, 7AH) recommended
Standby Time: 4 hours min. with 750 mA aux. load using 7 AH
battery
Circuit Protectors: PTC circuit breakers are used on battery
input to protect against reverse battery connections and on
alarm sounder output to protect against wiring faults (shorts). A
solid state circuit breaker is used on auxiliary power output to
protect against wiring faults (shorts)
Main Dialer
Formats Supported: ADEMCO High Speed, ADEMCO
4 + 2 Express, ADEMCO Low Speed, ADEMCO Contact ID,
Sescoa and Radionics Low Speed
Line Seize: Double Pole
Ringer Equivalence: 0.7B
Cabinet dimensions:
• 12-1/2" W X 14 1/2" H X 3" D
4208SNF
Eight-Zone
Expander Module
6160
Console
4944SN
Contact
4204
Relay
Module
4204CF
Supervised
NAC Module
Supports Up To
16 Conventional
Two-Wire
Smoke Detectors
4209U
Group Zoning
Module
4190SN
Remote Point
Module
4193SN
Serial Interface
Module
Panel
Linking
Module
VISTA-250BP
Symphony
ECP
Bus
5808LST
Wireless
Smoke
5890
Wireless PIR
5816
Door/Window
Transmitter
VISTA-250BP
5800
Series
Wireless
Devices
5869
Commercial
UL Wireless
Hold-up Button
5817CB Universal
Contact Monitoring
Transmitter
5881ENHC
Commercial Wireless Receiver
(Max Two)
ADEMCO VISTA-250BP
250 Zone UL Commercial Burglary Control Panel
4959SN
Overhead Door
Contact
Panel
Linking
Module
VistaKey V-Plex
Access Control
Module