LOCAL TEST MODE:
Prior to installation the local test mode should be performed.
With only power applied to the FSA module, press any button
within 3 seconds. All LEDs will light and the sounder will beep,
then all LEDs will sequentially light and turn off. The sounder
will beep once at the end of the test.
INSTALLATION:
For UL Installations: Mount the FSA module horizontally to a
duplex box (quad box for FSA-24). All wiring between the FSA
module and the control must be run in conduit.
CONNECTIONS AND SETTINGS:
Select and set an address for the FSA module, using its DIP
switch as shown in the table below. Each FSA module used
with the control must be assigned a unique address so the
control can identify the FSA module and communicate with it
properly. The address to be set is determined by the particular
control to be used, and the control's installation instructions
must be consulted.
Connections to the control's keypad wiring points are made
via 5-position terminal block TB1, a 5-pin plug or both (wire
color connections are the same).
TO ENABLE THE FSA UNIT:
At the control panel keypad, from the Data Field
Programming Mode, press #93 to display “ZONE PROG”.
Press 0 repeatedly to display the “DEVICE PROG?”
prompt. Press 1 to enter Device Programming.
The “DEVICE ADDRESS” prompt is displayed. The device
address identifies the device to the control. Enter the
2-digit FSA module address number to match the physical
address of the FSA module DIP switch settings (08-23).
Up to 4 FSA modules can be installed in the system. Each
requires a unique device address.
Press [(] to accept entry. The “DEVICE TYPE” prompt is
displayed. Enter 8 = Fire Display.
Press [(] to accept entry. The “RST FIRE PTN?” prompt is
displayed.
Enter 0 to disable the FSAs Silence/Reset button (default
mode).
Enter 1 to enable the FSAs Silence/Reset button to
Silence the fire alarm system when pressed once.
(Silence only)
Enter 2 to enable the FSA's Silence/Reset button to
Silence and then Reset the fire alarm system when pressed
twice.
Requires the approval of the AHJ.
Please Note: When the installation is Fire/Burg, a Burg
Zone should not be Installed (or enrolled) in the Fire
partition (partition 1). It will be Reset with a “Fire Reset”
and the system will lose Burg security.
Press [(] to accept entry. Be sure to set the FSA module
DIP switches to match the Device Address you have
enabled.
TO PROGRAM THE LEDS:
At the control panel keypad, from the Data Field
Programming Mode, press #93 to display “ZONE PROG”.
Press 0 repeatedly to display the “OUTPUT PROG?”
prompt.
Press 1 to enter Output Programming. The “ENTER RELAY
#” prompt is displayed.
Enter the 2-digit Relay / Output # (01 – 96). OR Enter 00
to Quit (00 = Quit).
Press [(] to accept entry. Refer to the control panel
installation and programming guide relay programming
section. Program the LEDs as if they were relays selecting
zone number, list, or type, start/stop instructions, etc. until
the “RELAY TYPE” prompt is displayed. At this prompt
enter 3 = FSA.
Press [(] to accept entry. The “ECP ADDRESS” prompt is
displayed. Enter the 2-digit ECP address of the FSA.
Press [(] to accept entry. The “LED #” prompt is displayed.
Enter the LED number to be associated with the zone
number, type, or list previously programmed.
Press [(] to accept entry.
Repeat for all LEDs at “ENTER RELAY #” prompt.
SYSTEM TEST MODE:
With the system installed and programmed, press the TEST
button. All LEDs will light and the sounder will beep, then all
LEDs will sequentially light and turn off. The sounder will beep
once at the end of the test.
47
FSA-8/FSA-24
Fire System Annunciator
00000
ECP Bus
Dip Switch
Optional
Keyswitch
Connection
SIDE
VIEW
All Switches shown
in Up position.
(ECP Address 23)
Terminal
Block
Connect to
Keypad
Terminals
1
2
3
4
DIP
Switch
Position
ECP Address
Down
Down
Down
Down
Up
Down
Down
Down
Down
Up
Down
Down
Up
Up
Down
Down
Down
Down
Up
Down
Up
Down
Up
Down
Down
Up
Up
Down
Up
Up
Up
Down
Down
Down
Down
Up
Up
Down
Down
Up
Down
Up
Down
Up
Up
Up
Down
Up
Down
Down
Up
Up
Up
Down
Up
Up
Down
Up
Up
Up
Up
Up
Up
Up
8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
ORDERING:
Part No. Description
FSA8 Fire Annunciator
FSA24 Fire Annunciator