34
Group #6 - Option 7 Restart Confirm Time on Repeated Single Zone
When this option is enabled (1), the confirm timer will be restarted whenever the first
to alarm zone is opened again within the confirm time window. When disabled (0), the
confirm timer will continue running as before and will not restart.
Group #6 - Option 8 Disable Keypad Unsets
This option can be used to prevent keypads from unsetting the system under normal
conditions. This may become a requirement for DD243 on systems that a controlled
by keyfobs (portable ACE). This option has 4 settings:
0 No
Keypads can always unset the system.
1 Always disable
The keypad can never unset the system. Unsetting can only be performed by a keyfob.
Note: If the panel becomes locked by accidental selection of this option, the panel can
be force unset by the following procedure:
1. Remove all power from the system.
2. Opened the panel lid tamper.
3. Re-apply power.
4. The system will power up unset in a tamper condition.
2 Full set only
The keypad cannot unset from a full set condition. When part set, it can disarm.
3 During Entry
The keypad can unset the system at any time, except during the normal entry time.
This option could be used to ensure users are always using their keyfobs but does not
lock them out completely when a keyfob is lost or damaged.