Wire Free Installation Hints and Tips
Notes on Wire Free detector location:
The Ademco Microtech 5800 range of wire free detectors can run at indoor ranges of
up to 60 meters from the receiver. However, there are many factors which can affect
this.
1. Metal objects can significantly attenuate the signals coming from wire free
detectors. Care should be taken to ensure that no metal cladding, cabling,
mirrors or pipes are near any detector or receiver, or in the straight line path
between the detector and the receiver.
2. Thick walls between the detector and receiver can reduce the signal strength.
Radio signals can pass easily through plaster board walls and wood panelling,
and slightly less well through brick. Thick stone walls will reduce the signals
significantly. This should be taken into account when planning the
location of detectors and receivers.
3. Sources of local radio interference could make reliable operation of a wire
free alarm system impossible. For example, the close proximity of a cell phone
mast, a taxi operator’s base station or heavy electrical equipment will give very
strong radio interference.
All the above factors should be taken into account when planning the installation of a
wire free alarm system. Remember that there will be some sites where wire free
systems are impractical due to one or more of the above factors causing insurmount-
able problems.
If the above guidelines are followed the Accord xpC and the 5800 detectors will give
many years of reliable operation.
Site Surveying
Before applying wire free installation, it is strongly advised that the proposed site is
properly surveyed using the Ademco Microtech survey kit, (Part No. 2021-026).
Walk Test
When walk testing zones, the RF receiver is automatically placed in a reduced sensi-
tivity mode to simulate a worst case scenario for the RF detectors. When leaving
programming mode, always walk test RF detectors to check and re-synchronise the
detectors with the panel.