System Programming — Group 9 Parameters
SNOITPOMETSYS
PUORGNOITPOTLUAFED
9.)seY=1,oN=0(senoZdettimOetacinummoC=1)0(
9.)seY=1,oN=0(langisteS/tesnUtrevnI=2)0(
9.)rebmunenoz=81,enoN=0(enozkconKelbuoD=3)0(
9.)seY=1,oN=0(timOenoZresU=4)1(
9.)seY=1,oN=0(teseR/tesnUnoslangiserotserdneS=5)0(
9.)seY=1,oN=0(dewollanoitaivedyrtnE=6)1(
9.)seY=1,oN=0(goltnevetnirP=7)0(
9)seY=1,oN=0(sgnittestluafedyrotcaF=8)0(
9.)seY=1,oN=0(noisreverawtfosweiV=9)0(
Table 3.16 System Parameters
Group 9 — Option 1 Communicate Omitted Zones
When choosing Contact I.D. as a communication format, zones can be omitted to
prevent them operating in this mode. This option allows these zones to communicate
with the central station.
This option has two settings:
0. No (Communicate omitted zones disabled)
1. Yes (Communicate omitted zones enabled)
This option defaults to 0 (Communicate omitted zones disabled).
Group 9 — Option 2 Invert Open/Close Signals
This option has two settings:
0. No (invert Open/Close disabled).
1. Yes (invert Open/Close enabled).
This option defaults to 0 (invert Open/Close disabled).
If this option is enabled (1), Set signals report a Code 4 signal on Channel 4. If
disabled (2), Unset signals report a Code 2 signal on Channel 4.
Group 9 — Option 3 Double Knock Zone
This option allows one zone to be programmed as a Double Knock zone. The control
panel will only acknowledge the Double Knock zone if it is activated twice within five
minutes, or once for more than ten seconds.
Note: Only one zone can be selected for double knock. If a zone is programmed as
Double Knock, unsetting and setting will not affect the Double Knock status.