Appendix D...contd.
SYSTEM OPTIONS
GROUP OPTION SELECTION
7 1=DUAL REPORTING (0=NO, 1=YES) (0)
7 2=DTMF OR PULSE DIALLING (0=PULSE, 1=DTMF) (1)
7 3=PREVENT FULL SET WITH LINE FAULT (0=NO, 1=YES) (0)
7 4=BELL DELAY (0=NO, 1=10 MINUTE DELAY) (0)
7 5=EXIT TERMINATE (0=NO, 1=FULL SET ONLY,
2=FULL + PART SET, 3=FULL + NIGHT SET, 4=ALL SETS) (0)
7 6=WHEN TO COMMUNICATE (0=FULL SET, 1=FULL & PART SET,
2=FULL & NIGHT SET, 3=ALL SETS) (3)
7 7=LINE FAULT MONITOR (0=OFF, 1=ON) (1)
7 8=DOWNLOADER OPTIONS (0=FULL ACCESS ALLOWED,
1=PREVENT ACCESS WHEN SET, 2=PREVENT UNSETTING) (1)
7 9=Zone Auto Omit (0=2 ACTIVATIONS THEN ZONE OMITTED,
1=1 ACTIVATIONS THEN ZONE OMITTED) (0)
GROUP OPTION SELECTION
8 1=COMMS CHANNEL 1 TRIGGER (2 DIGITS SELECTION, SEE TABLE 5) (01)
8 2=COMMS CHANNEL 2 TRIGGER (2 DIGITS SELECTION, SEE TABLE 5) (02)
8 3=COMMS CHANNEL 3 TRIGGER (2 DIGITS SELECTION, SEE TABLE 5) (03)
8 4=COMMS CHANNEL 4 TRIGGER (2 DIGITS SELECTION, SEE TABLE 5) (00)
8 5=COMMS CHANNEL 5 TRIGGER (2 DIGITS SELECTION, SEE TABLE 5) (00)
8 6=COMMS CHANNEL 6 TRIGGER (2 DIGITS SELECTION, SEE TABLE 5) (00)
8 7=COMMS CHANNEL 7 TRIGGER (2 DIGITS SELECTION, SEE TABLE 5) (07)
8 8=COMMS CHANNEL 8 TRIGGER (2 DIGITS SELECTION, SEE TABLE 5) (00)
8 9=PERIODIC TEST REPORT (0=NO, 1=24 HRS, 2=168 HRS [7 DAYS],
3=744 HRS [31 DAYS]) (0)
GROUP OPTION SELECTION
9 1=REPORT ZONE OMITS TO C/S (CONTACT ID ONLY) (0=NO, 1=YES) (0)
9 2=INVERT OPEN AND CLOSE SIGNALS (0=NO, 1=YES) (0)
9 3=DOUBLE KNOCK ZONE SELECTION (0=NO ZONE,
1-8=NO. OF ZONE FOR DOUBLE KNOCK) (0)
9 4=USER OMIT ZONE (0=NO, 1=YES) (1)
9 5=SEND RESTORE ON UNSET OR RESET (0=UNSET, 1=RESET) (0)
9 6=ENTRY DEVIATION PERMITTED (0=NO, 1=YES) (1)
9 7=PRINT EVENT LOG (0=NO, 1=YES) (0)
9 8=SET FACTORY DEFAULTS (THIS OPTION NEEDS TO BE ENTERED TWICE) (1=YES)
(0)
9
9=SHOW SOFTWARE VERSION (1=YES) (0)
GROUP OPTION
SELECTION
0 1=TECHNISTORE VERSION NO. (3 DIGIT ENTRY 000-255) (000)
0 2=CONFIRMED ALARM TIME WINDOW (0=45MINS 1=10MINS, 2=20MINS, 3=30MINS, 4=60MINS) (4)
0 3=REPORT LOW BATT IN CHANNEL 9 OR CONTACT ID (0=NO, 1=YES) (0)
0 4=RF KEYFOB SET/UNSET OPTIONS (SEE TABLE 6) (1)
0 5=TRANSMITTER SUPERVISION TIME WINDOW (0=2.5 HRS, 1=3.6 HRS, 2=8.4 HRS) (0)
0 6=AUDIBLE JAM & SUPERVISION LOSS (0=UNSET ONLY, 1=UNSET AND SET INT ONLY, (1)
2=UNSET AND SET EXT AND INT)
0 7=RF LOW BATTERY WARNING (0=NO AUDIBLE INDICATION, 1=UNSET ONLY,
2=ANY TIME) (1)
0 8=PREVENT SETTING WITH JAMMING SIGNAL DETECTED (0=NO, 1=YES) (1)
0 9=REPORT AC FAIL AS 6 IN
CHANNEL 9 AND 1 IN CHANNEL 1 (CHECK WITH ARC) OR CONTACT ID (0=NO, 1=YES) (0)
Table 6
KEYFOB SET/UNSET OPTIONS
0 = SET/UNSET DURING ENTRY
1 = SET/UNSET ANYTIME
2 = DISABLE KEYFOBS
IP1-1232 Issue 4
GROUP OPTION SELECTION
#6 1=REPORT CONFIRMED ALARMS (0=NO, 1=BEFORE ENTRY, 2=EXCEPT ENTRY, 3=ALWAYS) (1)
#6 2=TIMEOUT ALARM AFFECTS CONFIRM (0=NO, 1=YES) (0)
#6 3=WALKTHRU AFFECTS CONFIRM (0=NOT AFTER TIMEOUT, 1=WHENEVER ACTIVATED) (0)
#6 4=FULL RESET FOR UNCONFIRMED ALARM (0=USER, 1=FULL RESET REQUIRED) (0)
#6 5=SIGNAL LOCKED OUT ZONES (0=ON CONFIRM TIMEOUT, 1=ON BELL TIMEOUT) (0)
#6 6=ENTRY TIMER CLEARS CONFIRM COUNT (0=RESETS COUNT, 1=KEEPS COUNT) (1)
#6 7=RESTART CONFIRM TIME ON REPEATED SINGLE ZONE (0=NO, 1=YES) (0)
#6 8=DISABLE KEYPAD UNSET (0=NO, 1=ALWAYS DISABLE, 2=FULL SET ONLY, 3=DURING ENTRY TIME) (0)
CONFIRM OPTIONS (DD243)
T
able 5
COMMS TRIGGER OPTIONS
00 = DISABLED
01 = FIRE
02 = PA
03 = INTRUDER ALARM
04 = OPEN/CLOSE
05 = RF LOW BA
TTERY
06 = RF SUPERVISION FAIL
07 = CONFIRMED ALARM
08 = RF JAM
09 = TAMPER
10 = ABORT
11 = COMMS TEST
12 = PANEL LOW BATTER
Y
13 = AC LOSS
14 = ASSITANCE HOTKEY
15 = ZONE OMIT
3/8/02