x Program feature or option Permitted in UL864? Y/N Possible settings Settings permitted in UL 864 ✱27 TEST REPORT INTERVAL Y Enter 0001-9999 for th
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 8-2
9-1 SECTION 9 User Access Codes ••••••••••••••••••••••••••••••••••••••••••••••••• General Information The VISTA-128FBP system allows a total of 150
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 9-2 Level 6: Duress Codes • Sends a silent alarm to a central monitoring station if the user i
Section 9 – User Access Codes 9-3 Adding a Master, Manager, or Operator Code During user code entry, normal key depressions at other keypads in a par
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 9-4 PROMPT EXPLANATION XMT USER DATA 1 = YES 0 = NO If the user number is from 001-050 th
10-1 SECTION 10 Testing the System ••••••••••••••••••••••••••••••••••••••••••••••••• Battery Test When AC power is present, the VISTA-128FBP/VISTA-2
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 10-2 PROMPT EXPLANATION AUTO-TEST DET? 0=NO 1=YES Enter 1 (YES) to have the system automati
Section 10 – Testing the System 10-3 The system automatically exits the Test mode if there is no activity (no doors or windows are opened and closed,
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 10-4 Trouble Conditions Supervisory Messages Display Description SUPV + Zone Number This indic
Section 10 – Testing The System 10-5 To the Installer Regular maintenance and inspection (at least annually) by the installer and frequent testing by
xi Program feature or option Permitted in UL864? Y/N Possible settings Settings permitted in UL 864 1✱30 RF RECEIVER SUPERVISION CHECK-IN INTERVAL N
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 10-6
A-1 APPENDIX A Regulatory Agency Statements ••••••••••••••••••••••••••••••••••••••••••••••••• UL Installation Requirements UL This system may be use
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide A-2 UL609 Local Mercantile Premises/Local Mercantile Safe & Vault 1. All zones must be con
Appendix A – Regulatory Agency Statements A-3 FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENTS The user shall not make any changes or modifications
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide A-4 CANADIAN EMISSIONS STATEMENTS This Class B digital apparatus complies with Canadian ICES-00
B-1 APPENDIX B Summary of System Commands •••••••••••••••••••••••••••••••••••••••••••••••••• User Code Commands Add A User Code = User Code + 8 + Ne
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide B-2 Relay Control Commands Activate Relay for Current Partition = User Code + 0.
C-1 APPENDIX C Specifications •••••••••••••••••••••••••••••••••••••••••••••••••• VISTA-128FBP/VISTA-250FBP CONTROL Physical: 18"H X 14-1/2&quo
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide C-2
D-1 APPENDIX D Contact ID Codes •••••••••••••••••••••••••••••••••••••••••••••••••• TABLE OF CONTACT ID EVENT CODES Code Definition 110 Fire Alarm 1
xii Program feature or option Permitted in UL864? Y/N Possible settings Settings permitted in UL 864 2✱21 SUPERVISION PULSES FOR COMMUNICATIONS DEV
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide D-2 Code Definition 604 Fire Test 606 Listen-In to Follow 607 Burglary Walk-Test 608 Off-Norma
Appendix D – Contact ID Codes D-3 Alpha Event Description RFLB RST RF Low Battery Restore EXP RST Expansion Module Failure Restore TMPR RST Tamper
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide D-4
Index-1 Index •••••••••••••••••••••••••••••••••••••••••••••••••• # #93 Menu Mode Programming ...4-2 #93 Menu Mode Programming
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide Index-2 Bypass Commands ...6-8 C California State Fir
Index Index-3 First Communication ...7-3 First Test Report Time ...5-7 For
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide Index-4 P PABX Access Code...5-3 Panic Button or Spee
Index Index-5 Temporary Schedules Programming ...6-13 Test Report Interval...5-3 Testing The Syst
NOTES
THE LIMITATIONS OF THIS ALARM SYSTEM While this System is an advanced wireless security system, it does not offer guaranteed protection against bur
xiii Program feature or option Permitted in UL864? Y/N Possible settings Settings permitted in UL 864 3✱60 BELL 2 & AUX RELAY TIMEOUT Y Enter 0
For the latest warranty information, please go to: www.honeywell.com/security/hsc/resources/wa
NOTES
NOTES
V250FBP-SOC-V5VISTA-128FBP / VISTA-250FBPSUMMARY OF CONNECTIONSTRANSFORMERW/ENCLOSUREADEMCO No.1451(supplied)INPUT: 120VAC, 60HZ,
ÊK0376V2ŠÊK0376V2ŠÊK0376V2ŠÊK0376V2Š K0376V2 7/09 Rev. B 2 Corporate Center Drive, Suite 100P.O. Box 9040, Melville, NY 11747
xiv
1-1 SECTION 1 General Description ••••••••••••••••••••••••••••••••••••••••••••••••• SIA Installations The VISTA-128FBP and VISTA-250FBP are not cert
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 1-2 Arming/Disarming and Bypassing • Can arm the system with zones faulted (Vent Zone). These
Section 1 - General Description 1-3 • Can periodically and automatically perform a scheduled download. • Revision 4.0 and above panels can be downlo
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 1-4 BLACK -RED +YELLOW DATAGREEN DATABLACK -RED +YELLOW DATAGREEN DATABLACK -RED +YELLOW DATAGR
2-1 SECTION 2 Partitioning ••••••••••••••••••••••••••••••••••••••••••••••••• Theory of Partitioning This system provides the ability to arm and disa
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 2-2 The Common Lobby feature employs logic for automatic arming and disarming of the common lob
Section 2 – Partitioning 2-3 Sequence #2: Office 1 Office 2 Lobby Action User #2: (Armed) Disarms Disarms User #1: Disarms (Disarmed) (No change) U
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 2-4 The following is a typical display: S Y S T E M 1 2 3 4 5 6 7 8 S T A T U S R R N N A
3-1 SECTION 3 Installing the Control ••••••••••••••••••••••••••••••••••••••••••••••••• This section describes the procedures for mounting and wiring
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-2 RUN BELL WIRESIN CONDUITPLATECABINETMOUNTINGSCREWS(3)fire_burg_cab-001-V0PCBOARDRUN ALL REM
Section 3 - Installing the Control 3-3 Installing the Control's Circuit Board To install the circuit board in the cabinet, perform the following
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-4 REDKEYPADSBLACKGREENYELLOWCONTROLTERMINALS 12131411kypd_conn-001-V0 Figure 3-5: Keypad Con
Section 3 - Installing the Control 3-5 If you purchased a kit containing the PS24 Power Supply Module, you may use this module to convert one or both
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-6 ALARM INDICATING DEVICE TYPE MANUFACTURER MODEL # 4-Wire Wall Mount Horn/Strobe, 12/24V,
Section 3 - Installing the Control 3-7 Table 3-1: BELL 1 AND BELL 2 MAXIMUM DEVICE RATING NOTE: To use this table, the device Candela Setting and Horn
iii Table of Contents ••••••••••••••••••••••••••••••••••••••••••••••••• Commercial Fire and Burglary...
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-8 Supervising the Notification Appliance Circuits To wire the NAC using the supervision featu
Section 3 - Installing the Control 3-9 +--+-+•EOLPOWERSUPERVISIONRELAYMODULEEOLR-14-WIRE SMOKEDETECTORS2000OHMEOLRHEATDETECTOR+–BLK+-ZONE TERMINALS(15
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-10 power is lost. Zone 974 (Primary Dialer Supervision) must be enabled in order for the
Section 3 - Installing the Control 3-11 Dialer Operation When only the main dialer is enabled (field 3✳30 = 1,0), the system attempts to route all mes
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-12 UL • These smoke detectors are UL Listed for use with the VISTA-128FBP/VISTA-250FBP
Section 3 - Installing the Control 3-13 Wiring 4-Wire Smoke Detectors UL • Power to 4-wire smoke detectors must be supervised with an EOL device
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-14 GLASSBREAKDETECTORZONE 8 (+)(-)LATCHING TYPE GLASSBREAK DETECTOR LOOP2000OHMSEOLR 2726glas
Section 3 - Installing the Control 3-15 2k EOLR+TAMPERSWITCHSENSOR Figure 3-14: Wiring a Normally Open Sensor Loop for Tamper Supervision Installing
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-16 Compatible Polling Loop Devices Model Number Type 4297 Extender Module 4208SN 8 Zone V-P
Section 3 - Installing the Control 3-17 272526+polling_loop-012-V22928VPLEX-VSITOBURG DEVICESTOFIRE DEVICESNOTE: FIRE DEVICES MAYBE WIRED DIRECTLY TOT
Table of Contents iv Zone Response Type Definitions...
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-18 INPUT POLLING LOOPCONTROL PANELEXTENSION POLLING LOOP #1 4297COMBINED INPUT AND EXTENSION
Section 3 - Installing the Control 3-19 UL A response type 19 (24-Hour Trouble) must be programmed for zones 990 (1st receiver) and 988 (2nd receiver
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-20 5881ENHC-001-V0SCREW Figure 3-18: Installing the 5881ENHC with Tamper Protection TO CONTRO
Section 3 - Installing the Control 3-21 Transmitter Input Types All transmitters have one or more unique factory-assigned input (loop) codes. Transmi
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-22 Installing Output DevicesThe VISTA-128FBP/VISTA-250FBP supports up to 96 outputs. Each dev
Section 3 - Installing the Control 3-23 4204CF ADDRESS SETTINGSSWITCHNUMBER("—" means "OFF")0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 152
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-24 LED Indications Green Red Indication On Off Disarmed & Ready Off Off Disarmed &am
Section 3 - Installing the Control 3-25 Communicators Connected to the ECP The control can support an IP or GSM communications device (7845i-ent, 7845
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-26 Installing the Communicator To install the communications device, perform the following st
Section 3 - Installing the Control 3-27 The control panel kit you purchased comes with the appropriate transformer. Both transformers have a manually
Table of Contents v UL Installation Requirements...
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-28 Determining the Control’s Power Supply Load In the event of an AC power loss the VISTA-128
Section 3 - Installing the Control 3-29 3. In Worksheet 3, enter devices used on Auxiliary Power 2. Calculate standby and alarm currents, then add to
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-30 If you are using the PS24, skip the Battery Capacity Calculation Worksheet that follows an
Section 3 - Installing the Control 3-31 BLACKREDBLACKRED12VBATTERY12VBATTERY(IF REQUIRED)++BATTERY TABSMAIN PCB DUAL BATTERYHARNESS(2 PAIRSSUPPLIED)OB
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 3-32
4-1 SECTION 4 Programming ••••••••••••••••••••••••••••••••••••••••••••••••• NOTE: All references in this manual for number of zones, number of user
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 4-2 In either of the above cases, simply re-enter [✳] + the correct field number and then enter
Section 4 – Programming 4-3 Below are the main menu selections. For details refer to the VISTA-128FBP/VISTA-250FBP Programming Guide. MAIN MENU OPTION
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 4-4 MAIN MENU OPTIONS SCHEDULED CHK-IN 1 = YES 0 = NO 0 For defining the schedule for the s
Section 4 – Programming 4-5 Communication Defaults *45 PRIMARY FORMAT [1] ADEMCO Contact ID *46 LOW SPEED FORMAT (Prim) [0] ADEMCO Low Speed *47
vi List of Figures ••••••••••••••••••••••••••••••••••••••••••••••••• Figure 1-1: Isolating Fire Devices from Burglary Devices...
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 4-6 Communication Defaults for Zones (continued) ZONE # 1st 2nd ZONE # 1st 2nd ZONE # 1s
Section 4 – Programming 4-7 Type 09: Supervised Fire (Without Verification) Provides a fire alarm on a short circuit and a trouble condition on open c
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 4-8 Zone Input Type Definitions Each zone must be assigned an input type, which defines the whe
Section 4 – Programming 4-9 Using a Relay to Unlock a Door This control can be programmed so that a user can trigger a relay for 2 seconds (e.g., to u
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 4-10
5-1 SECTION 5 Data Field Descriptions ••••••••••••••••••••••••••••••••••••••••••••••••• About Data Field Programming The following pages list this c
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 5-2 FIELD TITLE and DATA ENTRIES EXPLANATION *10 Exit Delay #1 (partition-specific) Enter 03
Section 5 – Data Field Descriptions 5-3 FIELD TITLE and DATA ENTRIES EXPLANATION *23 Multiple Alarms (partition-specific) 0 = disable 1 = enable I
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 5-4 FIELD TITLE and DATA ENTRIES EXPLANATION *33 Primary Phone Number Enter 0-9; #11 for *,
Section 5 – Data Field Descriptions 5-5 FIELD TITLE and DATA ENTRIES EXPLANATION *44 Ring Detection Count Enter 00 to disable ring detection. Ent
vii Conventions Used in This Manual ••••••••••••••••••••••••••••••••••••••••••••••••• Before you begin using this manual, it is important that you un
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 5-6 FIELD TITLE and DATA ENTRIES EXPLANATION *54 Unattended Mode 0 = disable 1 = enable If
Section 5 – Data Field Descriptions 5-7 FIELD TITLE and DATA ENTRIES EXPLANATION *83 First Test Report Time Enter 00-07the for day (01 = Monday) En
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 5-8 FIELD TITLE and DATA ENTRIES EXPLANATION 1*13 System Sensor Reversing Relay 0 =use nei
Section 5 – Data Field Descriptions 5-9 Conditions That Affect Cross-Zone Operation • In the event of a continuous fault (lasting at least 5 minutes)
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 5-10 FIELD TITLE and DATA ENTRIES EXPLANATION 1*33 TouchTone with Rotary Backup 0 = disable
Section 5 – Data Field Descriptions 5-11 FIELD TITLE and DATA ENTRIES EXPLANATION 1*52 Send Cancel If Alarm + Off (partition-specific) 0 = disabl
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 5-12 FIELD TITLE and DATA ENTRIES EXPLANATION 1*76 Control Relay (partition-specific) 01-96
Section 5 – Data Field Descriptions 5-13 FIELD TITLE and DATA ENTRIES EXPLANATION 2*09 Open/Close Reports by Exception (partition-specific) 0 = dis
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 5-14 FIELD TITLE and DATA ENTRIES EXPLANATION 3*00 Check or TRBL Display 0 = CHECK 1 = TRBL
Section 5 – Data Field Descriptions 5-15 FIELD TITLE and DATA ENTRIES EXPLANATION 3*19 Auxiliary Input Alternate Function Enable 0 = disable 1 = en
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 5-16 FIELD TITLE and DATA ENTRIES EXPLANATION 3*59 Enable Bell 2 & Auxiliary Relay Chim
6-1 SECTION 6 Scheduling Options ••••••••••••••••••••••••••••••••••••••••••••••••• UL • You must program Bypass and Auto-Arm Fail reports for UL i
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 6-2 Exception Reports This option allows the reporting of openings and closings to the central
Section 6 – Scheduling Options 6-3 Open/Close Schedules Definitions General The open/close scheduling is controlled by one of three schedules. Each s
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 6-4 Scheduling Menu Mode The #80 Scheduling Menu Mode is used to program most of the scheduling
Section 6 – Scheduling Options 6-5 PROMPT EXPLANATION Access Sched. ? 1 = YES 0 = NO 0 Enter 1 to program access schedules. Refer to Limitation
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 6-6 Daily Open/Close Schedules Each partition can be assigned one daily open/close schedule, pl
Section 6 – Scheduling Options 6-7 Holiday Schedule Worksheet The following worksheet is an example of the worksheet found in the Programming Guide.
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 6-8 1. Enter the schedule number (01-20) and time window number (01-20), and note the day of t
Section 6 – Scheduling Options 6-9 Field *04 must be enabled for randomization. A user must initiate a random schedule by entering one of the followin
ix UL864 (Commercial Fire) Compliance ••••••••••••••••••••••••••••••••••••••••••••••••• General Requirements The VISTA-128FBP/VISTA250FBP control pan
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 6-10 ACTION CODES EXPLANATION ACTION SPECIFIER 30=Auto bypass – Zone list 31=Auto unbypass
Section 6 – Scheduling Options 6-11 Limitation of Access Schedules Limitation of Access is a means by which a user’s access code is limited to workin
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 6-12 Limitation of Access Schedules Programming To program access schedules enter Scheduling Me
Section 6 – Scheduling Options 6-13 Temporary Schedule Worksheet Partition/Windows Mon Tue Wed Thu Fri Sat Sun 1 Disarm Window Start Tim
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 6-14 User Scheduling Menu Mode The system provides up to 20 “timers” available to the end user
7-1 SECTION 7 Downloading Primer (Remote Downloading is not a UL Listed feature) ••••••••••••••••••••••••••••••••••••••••••••••••• General Informati
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 7-2 been selected at the station – otherwise Compass will disconnect). If Compass does not have
Section 7 – Downloading 7-3 Getting On-Line with a Control Panel At the protected premises, the control panel must be connected to the existing teleph
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide 7-4 Scheduled Download (For Burglary Use Only) The VISTA-128FBP/VISTA-250FBP can be programmed
8-1 SECTION 8 Setting the Real-Time Clock ••••••••••••••••••••••••••••••••••••••••••••••••• General Information This system provides a real-time clo
Comments to this Manuals