1-1
SECTION 1
General Description
••••••••••••••••••••••••••••••••••••••••••••••••
SIA Installations
The VISTA-128FBP and VISTA-250FBP are not certified as SIA compliant, but can be programmed for False Alarm
Reduction. To program for False Alarm Reduction, follow the SIA Guidelines noted in the applicable programming fields
.
About the VISTA-128FBP/VISTA-250FBP
The VISTA-128FBP/VISTA-250FBP is an 8-partition, UL Listed commercial fire and burglary control panel with the
following features:
Up to 128 zones for VISTA-128FBP; 250 zones for VISTA-250FBP (hardwired, polling loop, and wireless zones)
Up to 150 user codes for VISTA-128FBP; 250 user codes for VISTA-250FBP
Supervision of Notification Appliance Circuits, phone lines, keypads, RF receivers, and output devices
Scheduling capabilities (allows certain operations to be automated)
The VISTA-128FBP/VISTA-250FBP can interface with the following devices:
An ECP Communications Device that can send Contact ID messages
NOTE: All references in this manual for number of zones, number of user codes, number of access cards,
and the event log capacity, use the VISTA-250FBP’s features. The following table lists the differences
between the VISTA-128FBP and the VISTA-250FBP control panels. All other features are identical.
Feature VISTA-128FBP VISTA-250FBP
Number of Zones 128 250
Number of User Codes 150 250
Event Log Capacity 512 1000
Features
Hardwire and Optional Expansion Zones
Provides 8 hardwire zones.
Supports up to 16 2-wire smoke detectors each on zone 1 and zone 2 (32 total).
Automatically resets 4-wire smoke detectors if the Aux Relay is programmed for smoke reset (3*61 = 2).
Supports up to 50 2-wire latching glassbreak detectors on zone 8.
Supports up to 242 additional expansion zones (120 for the VISTA-128FBP) using a built-in polling (V-Plex) loop.
Supports up to 250 wireless zones (128 for the VISTA-128FBP) fewer if using hardwire and/or polling loop zones.
Can program burglary zones as silent in the alarm condition (alarm output is silent and the keypad does not display
or sound the alarm).
Provides three keypad panic keys: 1 + (A), + # (B), and 3 + # (C).
Peripherals Devices
Supports up to 31 addressable devices, (keypads, RF receivers, relay modules, etc.).
Supervises devices (keypads, RF receivers, and relay modules) and individual relays (up to 32), as well as system
zones (RF receivers and keypad panics).
Provides 96 outputs using 4204 and 4204CF Relay Modules, and V-Plex Relay Modules can activate outputs in
response to system events (alarm condition), at a specific time of day, at random times, and manually using the #70
Relay Command Mode.
Supports one additional style-Y supervised Notification Appliance Circuit using a 4204CF.
Supports the ADEMCO 4146 Keyswitch on any one of the system's eight partitions.
Supports the PS24 Power Supply Module, which supplies two 24VFW, 1.7A full-wave rectified, unfiltered special
application outputs.