Code Definition
604 Fire Test
606 Listen-In to Follow
607 Burglary Walk-Test
608 Off-Normal
611 Fire Walk-Test Point Tested
612 Fire Walk-Test Point Not Tested
Code Definition
621 Event Log Reset
625 Time/Date Reset
631 Exception Schedule Change
632 Access Schedule Change
912 Fire Alarm Silence
Event Log Alpha Descriptors
Alpha Event Description
FIRE Fire Alarm
DURESS Duress Alarm
PANIC Silent or Audible Panic Alarm
BURGLARY Burglary Alarm
EXP SHRT Polling Loop Short
RF EXPND Expander Module Failure
AUXILIARY Non-burglary Alarm
TROUBLE Trouble
AC LOSS AC Loss
LOW BATTERY System Low Battery
SYSTEM RESET System Reset
PROG CHANGE Program Change
BATTERY FAIL System Battery Failure
RF SUPR RF Supervision
V-PLEX SUPR V-Plex Supervision
RF LBAT RF Low Battery
EXP TRBL Expander Module Trouble
RF TRBL RF Trouble
TAMPER Tamper
FIRE TRB Fire Trouble
FAIL TO COMM Failure to Communicate
BELL TROUBLE Bell Trouble
DISARMED Disarmed
DISARMED-REM Disarmed Remotely
DISARMED-KEY Disarmed Via RF Key
DISARM-AUTO Auto-Disarm
CALL BACK Callback Requested
CANCEL Cancel
DISRMD-EARLY Disarmed Early
DISRMD-LATE Disarmed Late
MISSED DISRM Missed Disarm
SKED CHANGE Schedule Change
ACC SKED CHG Access Control Schedule Change
ARM FAILED Failed to Arm
DIALER SHUT Dialer Shutdown
SYSTEM SHUT System Shutdown
BYPASS Bypass
Alpha Event Description
SELF TEST Self-test
TEST ENTRY Manual Test Entry
TEST EXIT Manual Test Exit
LOG OVERFLOW Dialer Queue Overflow
LOG CLEARED Dialer Queue Cleared
TIME SET Time Set
TIME ERROR Time Error
PROGRM ENTRY Program Entry
PROGRAM EXIT Program Exit
Uxxx ADD BY User XXX Added BY
Uxxx DEL BY User XXX Deleted BY
Uxxx CHG BY User XXX Changed BY
PRINTER FAIL Event Log Printer Failure
PAGER FAILED Pager Failure
TESTED Zone Tested
UNTESTED Zone Untested
FAILED Zone Test Failed
RLY TRBL Relay Trouble
EXP TMPR Expansion Module Tamper
VENT BYPASS Vent Zone Bypass
RF JAM RF Jam Detected
JAM RSTR RF Jam Restore
FIRE RST Fire Alarm Restore
DURE RST Duress Alarm Restore
PNC RST Panic Alarm Restore
BURG RST Burglary Alarm Restore
EXP RST Expansion Module Restore
RF RST RF Restore
AUX RST Auxiliary Restore
MED RST Medical Restore
TRBL RST Trouble Restore
AC RESTORE AC Restore
LOW BATT RST System Low Battery Restore
RESET
PROG CHANGE Program Change
BAT TST FAIL Battery Test Failure